Complications of indwelling venous access devices in cancer patients.
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: We undertook this study to review our experience with indwelling vascular access devices in cancer patients to identify factors associated with complications. PATIENTS AND METHODS: A total of 322 indwelling devices were placed in 274 cancer patients by a single surgeon. Devices were placed via percutaneous insertion in 72% (231 of 322) and via venous cutdown in 28% (91 of 322). We placed external catheters in 209 of 322 patients (65%) and subcutaneous infusion ports in 113 of 322 (35%). RESULTS: Pneumothorax occurred in four of 231 (1.7%) of the percutaneously placed devices. Postoperative complications included sepsis and thrombosis, which necessitated premature removal of the devices. Device related sepsis occurred in 28 of 209 patients (13%) with catheters and six of 113 patients (5%) with subcutaneous ports. Thrombosis occurred in 21 of 209 patients (10%) with catheters and seven of 113 (6%) with subcutaneous ports. In 15 of 19 devices removed for thrombosis, the tip was above the T3 level. Seventeen devices were placed in the saphenous vein, with a complication rate similar to that observed in upper-body devices. CONCLUSION: We found a significantly (P < .05, chi 2 analysis) increased incidence of thrombotic complications in patients with triple-lumen catheters (10 of 48) compared with double-lumen catheters (11 of 160), as well as a significantly (P < .05) decreased mean time until catheter failure (40 v 146 days). We also observed a significant increase in the rate of thrombosis in patients with a catheter tip above the T3 level. We therefore recommend the use of fluoroscopy at the time of placement to assure adequate catheter length and tip position and the use of triple-lumen catheters only when necessary for concurrent drug administration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bern, M. M., Lokich, J. J., Wallach, S. R., Bothe, A., Benotti, P. N., Arkin, C. F., Greco, F. A., Huberman, M., & Moore, C. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-76-3-112-6-423 · Cited by 788
A modified right atrial catheter for access to the venous system in marrow transplant recipients.
Hickman, R. O., Buckner, C. D., Clift, R. A., Sanders, J. E., STEWART, P. S., & Thomas, E. D. (1979) · PubMed · Cited by 647
A silicone rubber atrial catheter for prolonged parenteral alimentation.
Broviac, J. W., Cole, J. J., & Scribner, B. H. (1973) · PubMed · Cited by 550
Infections Associated with intravascular lines
Maki, D. (1982) · Medical Entomology and Zoology · Cited by 118
Comparison of infections in hickman and implanted port catheters in adult solid tumor patients
Pegues, D. A., Axelrod, P. I., McClarren, C., Eisenberg, B. L., Hoffman, J. P., Ottery, F. D., Keidan, R. D., Boraas, M. C., & Weese, J. L. (1992) · Journal of Surgical Oncology · doi:10.1002/jso.2930490306 · Cited by 94
Cited by
Venous Thromboembolism Associated With Long-Term Use of Central Venous Catheters in Cancer Patients
Verso, M., & Agnelli, G. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.08.008 · Cited by 605
Deep-Vein Thrombosis of the Upper Extremities
Kucher, N. (2011) · New England Journal of Medicine · doi:10.1056/nejmcp1008740 · Cited by 373
DEBOURDEAU, P., FARGE, D., BECKERS, M., BAGLIN, C., BAUERSACHS, R. M., BRENNER, B., BRILHANTE, D., FALANGA, A., GEROTZAFIAS, G. T., HAIM, N., et al. (2013) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12071 · Cited by 316
Thrombotic Complications of Central Venous Catheters in Cancer Patients
Kuter, D. J. (2004) · The Oncologist · doi:10.1634/theoncologist.9-2-207 · Cited by 244
Catheter-Associated Thrombosis in Patients With Malignancy
Shivakumar, S. P., Anderson, D. R., & Couban, S. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2009.22.6126 · Cited by 77
“A triple-lumen Hickman-type catheter is associated with a higher incidence of thrombotic complications than a double-lumen catheter, possibly as a result of the increased occlusion of the blood vessel with the larger triple-lumen catheter.(26) The material of the catheter also influences the risk of thrombosis: prospe…”
Background
Metadata
- Authors
- Eastridge, B. J., & Lefor, A. T.
- Venue
- Journal of Clinical Oncology
- Published
- 1995-01
- Volume
- 13
- Issue
- 1
- Pages
- 233-238
- ISSN
- 0732-183X (ISSN-L)
- 1527-7755
- OpenAlex
- W2127250545
- Cited by
- 217
- References
- 5
- FWCI
- 22.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.