The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Comparison of Diameter and Perimeter Methods for Tumor Volume Calculation
Abstract
PURPOSE: Lesion volume is often used as an end point in clinical trials of oncology therapy. We sought to compare the common method of using orthogonal diameters to estimate lesion volume (the diameter method) with a computer-assisted planimetric technique (the perimeter method). METHODS: Radiologists reviewed 825 magnetic resonance imaging studies from 219 patients with glioblastoma multiforme. Each study had lesion volume independently estimated via the diameter and perimeter methods. Cystic areas were subtracted out or excluded from the outlined lesion. Inter- and intrareader variability was measured by using multiple readings on 48 cases. Where serial studies were available in noncystic cases, a mock response analysis was used. RESULTS: The perimeter method had a reduced interreader and intrareader variability compared with the diameter method (using SD of differences): intrareader, 1.76 mL v 7.38 mL (P < .001); interreader, 2.51 mL v 9.07 mL (P < .001) for perimeter and diameter results, respectively. Of the 121 noncystic cases, 23 had serial data. In six (26.1%) of those 23, a classification difference occurred when the perimeter method was used versus the diameter method. CONCLUSION: Variability of measurements was reduced with the computer-assisted perimeter method compared with the diameter method, which suggests that changes in volume can be detected more accurately with the perimeter method. The differences between these techniques seem large enough to have an impact on grading the response to therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Segmentation of MR Brain Images into Cerebrospinal Fluid Spaces, White and Gray Matter
Lim, K. O., & Pfefferbaum, A. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198907000-00006 · Cited by 309
Anatomic segmentation and volumetric calculations in nuclear magnetic resonance imaging
Kennedy, D. N., Filipek, P. A., & Caviness, V. S. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.20356 · Cited by 270
Jernigan, T. L. (1990) · Archives of Neurology · doi:10.1001/archneur.1990.00530010035015 · Cited by 257
Magnetic resonance imaging–based brain morphometry: Development and application to normal subjects
Filipek, P. A., Kennedy, D. N., Caviness, V. S., Rossnick, S., Spraggins, T. A., & Starewicz, P. M. (1989) · Annals of Neurology · doi:10.1002/ana.410250110 · Cited by 156
MRI Measurement of Brain Tumor Response: Comparison of Visual Metric and Automatic Segmentation
Clarke, L. P., Velthuizen, R. P., Clark, M., Gaviria, J., Hall, L., Goldgof, D. B., Murtagh, R. F., Phuphanich, S., & Brem, S. S. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00302-0 · Cited by 103
Segmentation techniques for the classification of brain tissue using magnetic resonance imaging
Cohen, G., Andreasen, N. C., Alliger, R. J., Arndt, S. V., Kuan, J. K., Yuh, W. T. C., & Ehrhardt, J. C. (1992) · Psychiatry Research Neuroimaging · doi:10.1016/0925-4927(92)90012-s · Cited by 90
Harris, G. J., Barta, P. E., Peng, L. W., Lee, S., Brettschneider, P. D., Shah, A. P., Henderer, J. D., Schlaepfer, T. E., & Pearlson, G. D. (1994) · PubMed · Cited by 69
Self-citationShenton, M. E., Kikinis, R., McCarley, R. W., Metcalf, D., Tieman, J., & Jolesz, F. A. (1991) · Schizophrenia Research · doi:10.1016/0920-9964(91)90037-r · Cited by 58
Automatic Outlining of Regions on CT Scans
Keller, J. M., Edwards, F. M., & Rundle, R. (1981) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198104000-00015 · Cited by 53
Research works printed but not linked: 2
- 10.1016/S0022-5223(98)70274-0 · doi:10.1016/s0022-5223(98)70274-0
- 10.1016/0925-4927(91)90029-P · doi:10.1016/0925-4927(91)90029-p
Cited by
Wen, P. Y., Macdonald, D. R., Reardon, D. A., Cloughesy, T. F., Sorensen, A. G., Galanis, E., DeGroot, J., Wick, W., Gilbert, M. R., Lassman, A. B., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.26.3541 · Cited by 3,836
Self-citationBatchelor, T. T., Sorensen, A. G., di Tomaso, E., Zhang, W.-T., Duda, D. G., Cohen, K. S., Kozak, K. R., Cahill, D. P., Chen, P.-J., Zhu, M., et al. (2007) · Cancer Cell · doi:10.1016/j.ccr.2006.11.021 · Cited by 1,769
Self-citationJain, R. K., di Tomaso, E., Duda, D. G., Loeffler, J. S., Sorensen, A. G., & Batchelor, T. T. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2175 · Cited by 1,405
Self-citationZanoni, M., Piccinini, F., Arienti, C., Zamagni, A., Santi, S., Polico, R., Bevilacqua, A., & Tesei, A. (2016) · Scientific Reports · doi:10.1038/srep19103 · Cited by 1,144
Kickingereder, P., Isensee, F., Tursunova, I., Petersen, J., Neuberger, U., Bonekamp, D., Brugnara, G., Schell, M., Kessler, T., Foltyn, M., et al. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(19)30098-1 · Cited by 454
Metadata
- Authors
- Sorensen, A. G., Patel, S., Harmath, C., Bridges, S., Synnott, J., Sievers, A., Yoon, Y.-H., Lee, E. J., Yang, M. C., Lewis, R. F., Harris, G. J., Lev, M., Schaefer, P. W., Buchbinder, B. R., Barest, G., Yamada, K., Ponzo, J., Kwon, H. Y., Gemmete, J., Farkas, J., Tievsky, A. L., Ziegler, R. B., Salhus, M. R. C., & Weisskoff, R.
- Venue
- Journal of Clinical Oncology
- Published
- 2001-01-15
- Volume
- 19
- Issue
- 2
- Pages
- 551-557
- ISSN
- 0732-183X (ISSN-L)
- 1527-7755
- OpenAlex
- W1947046122
- Cited by
- 270
- References
- 9
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.