The DOI matches its Crossref record.
Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts: Interim Report of a Prospective Comparative Trial
Open accessAbstract
Purpose: Debate on adjunct screening in women with dense breasts has followed legislation requiring that women be informed about their mammographic density and related adjunct imaging. Ultrasound or tomosynthesis can detect breast cancer (BC) in mammography-negative dense breasts, but these modalities have not been directly compared in prospective trials. We conducted a trial of adjunct screening to compare, within the same participants, incremental BC detection by tomosynthesis and ultrasound in mammography-negative dense breasts. Patients and Methods: Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts is a prospective multicenter study recruiting asymptomatic women with mammography-negative screens and dense breasts. Eligible women had tomosynthesis and physician-performed ultrasound with independent interpretation of adjunct imaging. Outcome measures included cancer detection rate (CDR), number of false-positive (FP) recalls, and incremental CDR for each modality; these were compared using McNemar’s test for paired binary data in a preplanned interim analysis. Results: Among 3,231 mammography-negative screening participants (median age, 51 years; interquartile range, 44 to 78 years) with dense breasts, 24 additional BCs were detected (23 invasive): 13 tomosynthesis-detected BCs (incremental CDR, 4.0 per 1,000 screens; 95% CI, 1.8 to 6.2) versus 23 ultrasound-detected BCs (incremental CDR, 7.1 per 1,000 screens; 95% CI, 4.2 to 10.0), P = .006. Incremental FP recall occurred in 107 participants (3.33%; 95% CI, 2.72% to 3.96%). FP recall (any testing) did not differ between tomosynthesis (FP = 53) and ultrasound (FP = 65), P = .26; FP recall (biopsy) also did not differ between tomosynthesis (FP = 22) and ultrasound (FP = 24), P = .86. Conclusion: The Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts’ interim analysis shows that ultrasound has better incremental BC detection than tomosynthesis in mammography-negative dense breasts at a similar FP-recall rate. However, future application of adjunct screening should consider that tomosynthesis detected more than 50% of the additional BCs in these women and could potentially be the primary screening modality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Contrast-enhanced Mammography: State of the Art
Jochelson, M. S., & Lobbes, M. B. I. (2021) · Radiology · doi:10.1148/radiol.2021201948 · Cited by 352
Screening for Breast Cancer in 2018—What Should We be Doing Today?
Seely, J. M., & Alhassan, T. (2018) · Current Oncology · doi:10.3747/co.25.3770 · Cited by 258
Artificial intelligence for breast cancer screening: Opportunity or hype?
Houssami, N., Lee, C. I., Buist, D. S. M., & Tao, D. (2017) · The Breast · doi:10.1016/j.breast.2017.09.003 · Cited by 106
Self-citation
Metadata
- Authors
- Tagliafico, A. S., Calabrese, M., Mariscotti, G., Durando, M., Tosto, S., Monetti, F., Airaldi, S., Bignotti, B., Nori, J., Bagni, A., Signori, A., Sormani, M. P., & Houssami, N.
- Venue
- Journal of Clinical Oncology
- Published
- 2016-06-01
- Volume
- 34
- Issue
- 16
- Pages
- 1882-1888
- ISSN
- 0732-183X (ISSN-L)
- 1527-7755
- OpenAlex
- W2293501394
- Cited by
- 239
- References
- 0
- FWCI
- 27.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts: Interim Report of a Prospective Comparative Trial. https://app.cochat.ai/papers/10.1200/jco.2015.63.4147
- The paper
- Tagliafico, A. S., Calabrese, M., Mariscotti, G., Durando, M., Tosto, S., Monetti, F., Airaldi, S., Bignotti, B., Nori, J., Bagni, A., Signori, A., Sormani, M. P., & Houssami, N. (2016). Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts: Interim Report of a Prospective Comparative Trial. Journal of Clinical Oncology. https://doi.org/10.1200/jco.2015.63.4147
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.