The DOI matches its Crossref record.
Major impact of personalized dosimetry using 90Y loaded glass microspheres SIRT in HCC: Final overall survival analysis of a multicenter randomized phase II study (DOSISPHERE-01)
Abstract
516 Background: 90Y loaded microsphere SIRT (radioembolization) is a treatment option in advanced HCC. However, no personalized dosimetric endpoints are currently used. The goal of this study was to compare the efficacy of 90Y loaded glass microsphere SIRT in HCC using a standard versus a personalized dosimetric approach. Methods: DOSISPHERE-01 was a multicenter, randomized phase 2 trial in unresectable HCC patients with at least one tumor ≥7cm. Treatment arm was randomly assigned (1:1) to standard dosimetry arm (SDA), with a goal to deliver 120±20Gy to the treated volume or to personalized dosimetry arm (PDA) with a goal to deliver at least 205Gy to the index lesion. The primary endpoint was the response rate (RR) of the index lesion according to EASL criteria. Secondary endpoints included dose response evaluation, safety and overall survival (OS). Results: Sixty HCC patients were randomized (PDA 31, SDA 29, intent to treat population-ITTP-), and 56 treated (28 in each arm). RR was significantly increased in the PDA versus the SDA, in the ITTP, respectively 64.5% versus 31% (p=0.0095) as in the safety population -SP- (treatment effectively received, personalized 35, standard 21), respectively 74.3% versus 14.3% (p<0.0001). Median OS was significantly increased in the PDA versus the SDA, in the ITTP, respectively 26.7m (CI 95%:11.7-NR) versus 10.6m (CI 95%:6-16.8), p=0.0096, HR=0.421 (95%CI:0.215-0.826), p=0.0119, as in the SP, respectively 26.7m (CI 95%:11.7- NR) versus 9.5m (CI 95%:4.8-14.9), p=0.0015, HR=0.342 (95%CI:0.171-0.683), p=0.0023. Median OS was 26.7m (CI 95%:13.5-NR) versus 6.0m (CI 95%:3.8-14.9) for the patients who received a tumor dose ≥205 Gy or <205 Gy respectively, p=0.0106, HR=0.336 (95%CI:0.154-0.735), p=0.0063. Treatment-related clinically relevant hepatic ≥grade 3 AEs were observed in 5.7% and 14.2% of the patients of the PDA and SDA arms, respectively, (p=ns). Conclusions: MAA SPECT/CT based personalized dosimetry is safe and dramatically increased RR and OS of HCC patients. These results question the interpretation of all phase 3 trials of SIRT designed without personalized dosimetry in HCC. Clinical trial information: 2015-A00894-45.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Relevant data to this point are presented in the DOSISPHERE-01 study, which compared personalized dosimetry to escalate tumor doses (mean normal liver dose of 119.7 Gy, with 1 patient receiving 150.3 Gy) with a nondosimetry group (mean liver dose of 79.2 Gy) ( 56 ).”
From Normal-Tissue Tolerance to Radiopharmaceutical Therapies, the Knowns and the Unknowns (2021) · cites this paper as [56]
In the citing paper
“Although liver function alterations occurred, they were viewed as manageable and there was only 1 case of hepatic failure in the dosimetry group (1/28, 3.6%).”
From Normal-Tissue Tolerance to Radiopharmaceutical Therapies, the Knowns and the Unknowns (2021) · cites this paper as [56]
Citations
Cited by
Locoregional therapies in the era of molecular and immune treatments for hepatocellular carcinoma
Llovet, J. M., De Baere, T., Kulik, L., Haber, P. K., Greten, T. F., Meyer, T., & Lencioni, R. (2021) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-020-00395-0 · Cited by 1,044
Normal-Tissue Tolerance to Radiopharmaceutical Therapies, the Knowns and the Unknowns
Wahl, R. L., Sgouros, G., Iravani, A., Jacene, H., Pryma, D., Saboury, B., Capala, J., & Graves, S. A. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262751 · Cited by 95
Personalised Dosimetry in Radioembolisation for HCC: Impact on Clinical Outcome and on Trial Design
Garin, É., Palard, X., & Rolland, Y. (2020) · Cancers · doi:10.3390/cancers12061557 · Cited by 59
“In DOSISPHERE-01 study exclusion of patients, where it is not possible to spare from radiation, at least 30% of the liver volume is a good point, because it is possible to increase doses without increasing liver toxicities [53].”
BackgroundSelf-citationPersonalized Dosimetry in Targeted Radiation Therapy: A Look to Methods, Tools and Critical Aspects
Danieli, R., Milano, A., Gallo, S., Veronese, I., Lascialfari, A., Indovina, L., Botta, F., Ferrari, M. E., Cicchetti, A., Raspanti, D., et al. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12020205 · Cited by 60
“In addition, for a few therapies, the first promising signs are emerging, showing that the implementation of treatment planning based on dosimetry brings great benefits for the patients compared to the standard approach [43,116,117].”
BackgroundKolligs, F. T., Arnold, D., Golfieri, R., Pech, M., Peynırcıoğlu, B., Pfammatter, T., Ronot, M., Sangro, B., Schaefer, N. G., Maleux, G. A., et al. (2022) · JHEP Reports · doi:10.1016/j.jhepr.2022.100633 · Cited by 48
“…dosimetry model than the standard dose calculation model using glass microspheres in patients with unresectable, locally advanced HCC. 23,24 This suggests that further optimising selection of patients, treatment application and the dosimetry models may improve survival outcomes of…”
Metadata
- Authors
- Garin, E., Tzelikas, L., Guiu, B., Chalaye, J., Edeline, J., De Baere, T., Tacher, V., Robert, C., Assenat, E., Terroir-Cassou-Mounat, M., Regnault, H., Palard, X., Laffont, S., Campillo-Gimenez, B., & Rolland, Y.
- Affiliations
- Cancer Institute Eugène Marquis, Rennes, France;
- Institut Gustave Roussy (FR)
- Centre Hospitalier Universitaire de Montpellier (FR)
- Centre Hospitalier Universitaire Henri-Mondor (FR)
- Centre Eugène Marquis (FR)
- Institut Gustave Roussy, Villejuif, France;
- CHU Montpellier, Montpellier, France;
- Centre Eugene-Marquis, Rennes, France;
- ORCID
- Venue
- Journal of Clinical Oncology
- Published
- 2020-02-01
- Volume
- 38
- Issue
- 4_suppl
- Pages
- 516-516
- ISSN
- 0732-183X (ISSN-L)
- 1527-7755
- OpenAlex
- W3005463459
- Cited by
- 31
- References
- 0
- Citations by year
- 2025: 1 · 2024: 4 · 2023: 2 · 2022: 7 · 2021: 6 · 2020: 10
- Type
- conference abstract
- Language
- en
- Open access
- closed
- Locations
- Journal of Clinical Oncology (publishedVersion)
- Funders
- BTG UK LtD
- Topics
- Health Sciences › Medicine › Hepatology › Hepatocellular Carcinoma Treatment and Prognosis
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- personalized dosimetry, yttrium-90, glass microspheres, radioembolization, hepatocellular carcinoma, overall survival, tumor response rate, dose escalation, unresectable liver cancer, dose-response relationship, treatment safety, liver function decline
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Major impact of personalized dosimetry using 90Y loaded glass microspheres SIRT in HCC: Final overall survival analysis of a multicenter randomized phase II study (DOSISPHERE-01). https://app.cochat.ai/papers/10.1200/jco.2020.38.4_suppl.516
- The paper
- Garin, E., Tzelikas, L., Guiu, B., Chalaye, J., Edeline, J., De Baere, T., Tacher, V., Robert, C., Assenat, E., Terroir-Cassou-Mounat, M., Regnault, H., Palard, X., Laffont, S., Campillo-Gimenez, B., & Rolland, Y. (2020). Major impact of personalized dosimetry using 90Y loaded glass microspheres SIRT in HCC: Final overall survival analysis of a multicenter randomized phase II study (DOSISPHERE-01). Journal of Clinical Oncology. https://doi.org/10.1200/jco.2020.38.4_suppl.516
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.