Accelerated Solvent Extraction
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Extraction of solid and semisolid samples using liquid solvents is a common practice in nearly every analytical laboratory. Years of empirical testing have resulted in rugged and reproducible methodologies for a wide range of analyte classes. However, recent concerns regarding the volumes of organic solvents used (with the associated human exposure), along with increased purchase and disposal costs, have emphasized the need for more efficient sample extraction methods. In response to these concerns, accelerated solvent extraction (ASE ® , Dionex Corporation, Salt Lake City, UT) was introduced. Since its introduction in 1995, ASE has grown rapidly as an accepted alternative to traditional extraction methods. Accelerated solvent extraction takes advantage of the enhanced solubilities that occur as the temperature of a liquid solvent is increased. Increasing the temperature of solvent results in a decrease in viscosity, allowing better penetration of the sample matrix. In addition, analyte diffusion from the sample matrix into the solvent and overall solvent capacity are increased. In traditional Soxhlet extraction, the solvent that comes into contact with the sample has passed through a cooling condenser, and is therefore close to room temperature at the point of contact. The time required to complete Soxhlet extractions ranges from 6 to 48 h. Semi-automated Soxhlet systems that immerse the sample into boiling solvent are available. This increase in the temperature of the contacting solvent shortens the required extraction time to ∼2 h. Using these systems, a further increase in temperature beyond the boiling point of the solvent is not possible due to solvent loss because these systems operate at atmospheric pressure. However, a continued increase in the temperature should continue to enhance the extraction process. This can be accomplished by applying pressure, which maintains the solvent in its liquid state beyond its atmospheric boiling point. This is the theoretical basis for ASE technology and represents the next step in liquid solvent extraction of environmental samples. There are, of course, limits to which raising the temperature is feasible, due to thermal degradation concerns. However, as evidenced by data published to date, there is room to continue raising the temperature, thereby improving the extraction efficiency, without risking analyte degradation in environmental samples. As the extraction efficiency is increased, the time required to perform extractions and the amount of solvent needed is reduced. When performing ASE, a 10-g sample can be extracted in ∼12 min using 12–15 mL of solvent. As the sample size is increased (33 mL volume maximum), the amount of solvent used increases proportionally (45–50 mL maximum), but the total extraction time remains unchanged. The short extraction times and small solvent usage make this technique amenable to automation. Samples loaded into stainless steel extraction vessels (11, 22, or 33 mL internal volume) are extracted sequentially into standard 40- or 60-mL glass collection vials. After extraction, the spent sample remains in the cell, whereas the extract is immediately ready for processing. The system is designed to extract up to 24 samples unattended. Because existing solvent-based extraction methods can be readily transferred to ASE technology, methods development is greatly simplified. Existing sample preparation and postextraction processing steps remain in place because the extracts generated by ASE will be of very nearly the same composition as those generated with the existing solvent-based extraction technique. The large range of polarities and solvent strengths available when using liquid solvents, including solvent mixtures, allows a high degree of flexibility and selectivity when developing methods for new sample matrices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schäfer, K. (1998) · Analytica Chimica Acta · doi:10.1016/s0003-2670(97)00587-4 · Cited by 184
Cited by
Qualitative and Quantitative Analysis of Mycotoxins
Rahmani, A., Jinap, S., & Soleimany, F. (2009) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/j.1541-4337.2009.00079.x · Cited by 238
Research advances for the extraction, analysis and uses of anthraquinones: A review
Duval, J., Pecher, V., Poujol, M., & Lesellier, E. (2016) · Industrial Crops and Products · doi:10.1016/j.indcrop.2016.09.056 · Cited by 226
Carrasco-Pancorbo, A., Navas-Iglesias, N., & Cuadros-Rodríguez, L. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.12.005 · Cited by 100
Bioactive compounds from micro-algae and its application in foods: A review
Siddhnath, Surasani, V. K. R., Singh, A., Singh, S. M., Hauzoukim, Murthy, L. N., & Baraiya, K. G. (2024) · Discover Food · doi:10.1007/s44187-024-00096-6 · Cited by 42
Metadata
- Authors
- Luthria, D., Vinjamoori, D., Noel, K., & Ezzell, J.
- Venue
- Oil Extraction and Analysis
- Publisher
- AOCS Publishing
- Published
- 2019-06-07
- Pages
- 25-38
- OpenAlex
- W257961447
- Cited by
- 40
- References
- 1
- FWCI
- 2.24
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerated Solvent Extraction. https://app.cochat.ai/papers/10.1201/9780429104527-3
- The paper
- Luthria, D., Vinjamoori, D., Noel, K., & Ezzell, J. (2019). Accelerated Solvent Extraction. Oil Extraction and Analysis. https://doi.org/10.1201/9780429104527-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.