The Electrocardiographic Inverse Problem
The DOI matches its Crossref record.
Abstract
Using the boundary element method in conjunction with Tikhonov zero-order regularization, we have computed epicardial potentials from body surface potential data in a realistic geometry heart-torso system. The inverse-reconstructed epicardial potentials were compared to the actual measured potentials throughout a normal cardiac cycle. Potential features (maxima, minima) were recovered with an accuracy better than 1 cm in their location. In this chapter, we use these data to illustrate and discuss computational issues related to the inverse-reconstruction procedure. These include the boundary element method, the choice of a regularization scheme to stabilize the inversion, and the effects of incorporating a priori information on the accuracy of the solution. In particular, emphasis is on the use of temporal information in the regularization procedure. The sensitivity of the solution to geometrical errors and to the spatial and temporal resolution of the data is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Noninvasive electrocardiographic imaging for cardiac electrophysiology and arrhythmia
Ramanathan, C., Ghanem, R. N., Jia, P., Ryu, K., & Rudy, Y. (2004) · Nature Medicine · doi:10.1038/nm1011 · Cited by 646
Self-citationActivation and repolarization of the normal human heart under complete physiological conditions
Ramanathan, C., Jia, P., Ghanem, R., Ryu, K., & Rudy, Y. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0601533103 · Cited by 261
Oster, H. S., Taccardi, B., Lux, R. L., Ershler, P. R., & Rudy, Y. (1997) · Circulation · doi:10.1161/01.cir.96.3.1012 · Cited by 256
Self-citationBody surface electrocardiographic mapping for non-invasive identification of arrhythmic sources
Shah, A. J., Hocini, M., Pascale, P., Roten, L., Komatsu, Y., Daly, M., Ramoul, K., Denis, A., Derval, N., Sacher, F., et al. (2013) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2013.2.1.16 · Cited by 37
Non-invasive mapping of cardiac arrhythmias
Shah, A., Hocini, M., Haissaguerre, M., & Jaïs, P. (2015) · Current Cardiology Reports · doi:10.1007/s11886-015-0616-6 · Cited by 22
Metadata
- Authors
- Yoram, R., & Oster, H. S.
- Venue
- High-Performance Computing in Biomedical Research
- Publisher
- CRC Press
- Published
- 2020-09-10
- Volume
- 20
- Issue
- 1-2
- Pages
- 135-155
- OpenAlex
- W2396707042
- Cited by
- 83
- References
- 0
- FWCI
- 10.91
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Electrocardiographic Inverse Problem. https://app.cochat.ai/papers/10.1201/9781003068136-9
- The paper
- Yoram, R., & Oster, H. S. (2020). The Electrocardiographic Inverse Problem. High-Performance Computing in Biomedical Research. https://doi.org/10.1201/9781003068136-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.