Discharge measurement structures
The DOI matches its Crossref record.
Abstract
This chapter introduces calculation procedures for discharge measurement structures. It focuses on a rational expression for discharge in terms of typical flow quantities and the geometry of the structure. The chapter presents the general one-dimensional flow equations, and a demonstration that critical flow can occur if either the cross-sectional area has a local minimum or the bottom geometry is characterized by a local maximum. It describes devices that involve gradually varied channel geometries, and shows that classical critical flow theory fits well with observations, and that discharges can be determined rationally. The chapter discusses weirs having rapidly varying geometry such as thin plate weirs, and explains the intermediate structures having moderately varied channel geometry such as broad-crested weirs and flumes of the Parshall type. It also discusses the WES-standard spillways often used on dams with high discharges, and miscellaneous discharge measurement structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Global monthly water stress: 1. Water balance and water availability
van Beek, L. P. H., Wada, Y., & Bierkens, M. F. P. (2011) · Water Resources Research · doi:10.1029/2010wr009791 · Cited by 555
Metadata
- Authors
- HAGER, W. H.
- Venue
- Discharge Characteristics
- Publisher
- Routledge
- Published
- 2017-11-22
- Pages
- 3-54
- OpenAlex
- W1517207747
- Cited by
- 241
- References
- 0
- FWCI
- 90.65
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Discharge measurement structures. https://app.cochat.ai/papers/10.1201/9781315141343-2
- The paper
- HAGER, W. H. (2017). Discharge measurement structures. Discharge Characteristics. https://doi.org/10.1201/9781315141343-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.