The DOI matches its Crossref record.
Super-Resolution Imaging
Abstract
© 2011 by Taylor and Francis Group, LLC. The relation between sensor resolution and the optics of a digital camera is determined by the Nyquist sampling theorem: the sampling frequency should be larger than twice the maximum frequency of the image content coming out of the optical system. If a lower resolution is used, the output is aliased. Aliasing in digital images is often considered as a nuisance and (both optical and digital) filters are designed to avoid aliasing in digital cameras. However, aliasing also contains extra high-frequency information with additional details about the scene. Super-resolution algorithms extract the information present in the aliasing to reconstruct a higher-resolution image.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Super-resolution: a comprehensive survey
Nasrollahi, K., & Moeslund, T. B. (2014) · Machine Vision and Applications · doi:10.1007/s00138-014-0623-4 · Cited by 684
Reconstruction of fetal brain MRI with intensity matching and complete outlier removal
Kuklisova-Murgasova, M., Quaghebeur, G., Rutherford, M. A., Hajnal, J. V., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.07.004 · Cited by 426
Super-Resolution from Noisy Data
Candès, E. J., & Fernandez-Granda, C. (2013) · Journal of Fourier Analysis and Applications · doi:10.1007/s00041-013-9292-3 · Cited by 392
Fast Direct Super-Resolution by Simple Functions
Yang, C.-Y., & Yang, M.-H. (2013) · 2013 IEEE International Conference on Computer Vision · doi:10.1109/iccv.2013.75 · Cited by 332
Nonparametric Blind Super-resolution
Michaeli, T., & Irani, M. (2013) · 2013 IEEE International Conference on Computer Vision · doi:10.1109/iccv.2013.121 · Cited by 332
Metadata
- Venue
- CRC Press eBooks
- Publisher
- CRC Press
- Published
- 2017-12-19
- OpenAlex
- W2914829730
- Cited by
- 176
- References
- 0
- Type
- reference entry
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Super-Resolution Imaging. https://app.cochat.ai/papers/10.1201/9781439819319
- The paper
- Super-Resolution Imaging. (2017). CRC Press eBooks. https://doi.org/10.1201/9781439819319
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.