The DOI matches its Crossref record.
Optical Coherence Tomography
Abstract
The power of nonlinear imaging stems from the multiphoton interaction requirement. Since photon incidence is a statistical process, one can calculate the number of photons (n) absorbed per incident light pulse in a two-photon process (Denk, Strickler, and Webb 1990), that is, = σ pi τ λn P NA f h c where σ2P is the two-photon absorption cross section, P is the average incident power, NA is the numerical aperture of the imaging lens, τp and fp are the incident light repetition rate and pulsewidth, h is the Planck’s constant, c the speed of light, and λ the incident light wavelength. The incident beam intensity drops roughly as the square of the distance from the focal spot. Combined with the quadratic dependence of absorption on incident power, the excitation probability of a fluorophor near the focal spot decreases as the fourth power of the distance of the fluorophor from the focal spot.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Staurenghi, G., Sadda, S., Chakravarthy, U., & Spaide, R. F. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.02.023 · Cited by 861
Jia, Y., Bailey, S. T., Wilson, D. J., Tan, O., Klein, M. L., Flaxel, C. J., Potsaid, B., Liu, J. J., Lu, C. D., Kraus, M. F., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.034 · Cited by 729
Optical coherence tomography angiography of the foveal avascular zone in diabetic retinopathy
Freiberg, F. J., Pfau, M., Wons, J., Wirth, M. A., Becker, M. D., & Michels, S. (2016) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-015-3148-2 · Cited by 299
Dry Age-Related Macular Degeneration: Mechanisms, Therapeutic Targets, and Imaging
Bowes Rickman, C., Farsiu, S., Toth, C. A., & Klingeborn, M. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-12757 · Cited by 282
Evaluation of Age-related Macular Degeneration With Optical Coherence Tomography
Keane, P. A., Patel, P. J., Liakopoulos, S., Heussen, F. M., Sadda, S. R., & Tufail, A. (2012) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2012.01.006 · Cited by 280
Metadata
- Authors
- Liang, W., Mavadia, J., & Li, X.
- Venue
- Series in Medical Physics and Biomedical Engineering
- Publisher
- Taylor & Francis
- Published
- 2013-11-25
- Pages
- 135-170
- ISSN
- 2155-2312 (ISSN-L)
- OpenAlex
- W3154907138
- Cited by
- 215
- References
- 0
- FWCI
- 150.89
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical Coherence Tomography. https://app.cochat.ai/papers/10.1201/b16289-14
- The paper
- Liang, W., Mavadia, J., & Li, X. (2013). Optical Coherence Tomography. Series in Medical Physics and Biomedical Engineering. https://doi.org/10.1201/b16289-14
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.