CoChat

A Pilot Study of Inexpensive Sleep-Assessment Devices

Edinger, Jack D., Means, Melanie K., Stechuchak, Karen M., Olsen, Maren K. · 2004 · Behavioral Sleep Medicine
Cited by 65

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Polysomnography (PSG), the gold standard sleep-assessment methodology, is impractical for many applications. Although alternative assessment methodologies are available, it is not clear which most correlates with PSG measures. This study compared sleep log (SL), actigraphy (ACT), and the REMview (RV) device for estimating PSG sleep measures. Thirty-three participants with various sleep-disorder diagnoses underwent 1 night of monitoring with PSG, RV, ACT, and SL. RV provided accurate estimates of most sleep variables. The accuracy of ACT and SL estimates depended on the sleep variable. These findings indicate that the selection of an alternative methodology should consider the sleep measure of interest in addition to the relative merits and drawbacks of each device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1207/s15402010bsm0201_4

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 65

Metadata

Authors
Edinger, J. D., Means, M. K., Stechuchak, K. M., & Olsen, M. K.
Venue
Behavioral Sleep Medicine
Published
2004-02
Volume
2
Issue
1
Pages
41-49
ISSN
  • 1540-2002 (ISSN-L)
  • 1540-2010
OpenAlex
W2078296747
Cited by
65
References
1
FWCI
6.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Pilot Study of Inexpensive Sleep-Assessment Devices. https://app.cochat.ai/papers/10.1207/s15402010bsm0201_4
The paper
Edinger, J. D., Means, M. K., Stechuchak, K. M., & Olsen, M. K. (2004). A Pilot Study of Inexpensive Sleep-Assessment Devices. Behavioral Sleep Medicine. https://doi.org/10.1207/s15402010bsm0201_4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.