Impact of Extractables/Leachables from Filter Materials on the Stability of Protein-Based Pharmaceutical Products
Abstract
The manufacturing of biopharmaceutical drug solutions can involve close contact with various polymeric components, including common filter membranes. Potential leachable substances from filters may interact with the protein and thereby increase the structural damage and aggregation. The main aim of the study deals with the assessment of extractable and leachable (E/L) from different filters and the potential effect of E/Ls on protein (human granulocyte-colony stimulating factor (rh-GCSF) stability. The present study examines the E/L profile of five different polymeric filter membranes using various chromatographic techniques including LC–MS and GC–MS. In order to investigate their effect on protein stability, G-CSF (human granulocyte colony-stimulating factor) formulations were spiked with filter leachable stock solutions at two different pH levels. The spiked formulations were further analyzed with respect to their aggregation behavior. The results demonstrated a higher E/L content in the case of polyamide (PA), polycarbonate (PC), and polyethersulfone (PES) filters as compared to the polytetrafluoroethylene (PTFE) and regenerative cellulose (RC) filter materials. The E/L from RC and PES was found surface-active, whereas E/L from PA and RC significantly altered the particle size/structure resulting in the aggregation of proteins. Furthermore, bisphenol A was found to be one of the E/L substances from PC filters and can impose significant health problems when administered along with pharmaceutical products. The present study reports a qualitative rank ordering of the filter membranes in terms of their propensity to generate E/Ls and thus can be helpful in selecting a suitable membrane filter.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
These materials retain mechanical strength and microbial barrier function even after gamma irradiation, making them ideal for sterile filtration systems.
“These materials retain their mechanical strength and microbial barrier function even after gamma irradiation, making them ideal for sterile filtration systems.”
From Single-use solutions for PUPSIT: requirements, challenges, and solutions (2026) · cites this paper as Kushwah, et al. 2022
Other materials such as PEEK, PP, and silicone also play important roles, with PEEK providing excellent mechanical and thermal properties for high-performance connectors and housings, and silicone offering flexibility and biocompatibility, though it requires thorough evaluation for extractables.
“Other materials such as polyether ether ketone (PEEK), polypropylene (PP), and silicone also play important roles, with PEEK providing excellent mechanical and thermal properties for high-performance connectors and housings, and silicone offering flexibility and biocompatibility, though it requires thorough evaluation for extractables (Kushwah, et al. 2022; Huang, et al. 2011; Jenke et al. 2006).”
From Single-use solutions for PUPSIT: requirements, challenges, and solutions (2026) · cites this paper as Kushwah, et al. 2022
Materials like PES, HPPE, UHMWPE, and PVDF are commonly used due to their exceptional chemical resistance, thermal stability, and low permeability.
“Materials like polyethersulfone (PES), polyethylene (high-performance polyethylene (HPPE), ultra-high molecular weight polyethylene (UHMWPE)), and polyvinylidene fluoride (PVDF) are commonly used due to their exceptional chemical resistance, thermal stability, and low permeability.”
From Single-use solutions for PUPSIT: requirements, challenges, and solutions (2026) · cites this paper as Kushwah, et al. 2022
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 19
- Jenke DR, et al. Accumulation of extractables in buffer solutions from a polyolefin plastic container. Int J Pharm. Jun. 2005;297(1- 2):120-33. https:// doi. org/ 10. 1016/j. ijpha rm. 2005. 03. 010. · DOI
- Behme S. Manufacturing of pharmaceutical proteins: from tech- nology to economy. John Wiley & Sons; 2021. https:// www. wiley. com/ en-us/ Manuf actur ing+ of+ Pharm aceut ical+ Prote ins% 3A+ From+ Techn ology+ to+ Econo my% 2C+ 3rd+ Editi on-p-97835 27833 801.
- Akers MJ. Sterile drug products: formulation, packaging, manu- facturing and quality. CRC Press; 2016. https:// www. taylo rfran cis. com/ books/ mono/ 10. 3109/ 97814 20020 564/ steri le-drug-produ cts-micha el-akers. · DOI
- Huang M, Horwitz TS, Zweiben C, Singh SK. Impact of extracta- bles/leachables from filters on stability of protein formulations. J Pharm Sci. 2011;100(11):4617-30.
- Riley CM, Rosanske TW, Reid GL, editors. Specification of drug substances and products: development and validation of analytical methods. Elsevier; 2020. https:// www. elsev ier. com/ books/ speci ficat ion-of-drug-subst ances-and-produ cts/ riley/ 978-0-08-102824-7
- T. Arakawa, S. J. Prestrelski, L. O. Narhi, T. C. Boone, and W. C. Kenney, "Cysteine 17 of recombinant human granulocyte-colony stimulating factor is partially solvent-exposed," J. Protein Chem. 1993 125, vol. 12, no. 5, pp. 525-531, Oct. 1993, https:// doi. org/ 10. 1007/ BF010 25117 · DOI
- B. H. Do et al., "Granulocyte colony-stimulating factor (GCSF) fused with Fc domain produced from E. coli is less effective than polyethylene glycol-conjugated GCSF," Sci. Reports 2017 71, vol. 7, no. 1, pp. 1-9, Jul. 2017, https:// doi. org/ 10. 1038/ s41598-017-06726-7 · DOI
- Oh-Eda M, et al. O-linked sugar chain of human granulocyte colony-stimulating factor protects it against polymerization and denaturation allowing it to retain its biological activity*. J Biol Chem. 1990;265(20):11432-5. https:// doi. org/ 10. 1016/ S0021- 9258(19) 38416-9. · DOI
- Raso SW, et al. Aggregation of granulocyte-colony stimulating factor in vitro involves a conformationally altered monomeric state. Protein Sci. 2005;14(9):2246-57. https:// doi. org/ 10. 1110/ ps. 05148 9405. · DOI
- Hübel K, Engert A. Clinical applications of granulocyte col- ony-stimulating factor: an update and summary. Ann Hematol. 2003;82(4):207-13. https:// doi. org/ 10. 1007/ s00277-003-0628-y. · DOI
- Hill CP, Osslund TD, Eisenberg D. The structure of granulocyte- colony-stimulating factor and its relationship to other growth fac- tors. Proc Natl Acad Sci U S A. 1993;90(11):5167-71. https:// doi. org/ 10. 1073/ pnas. 90. 11. 5167. · DOI
- Prakash A, Medhi B, Chopra K. Granulocyte colony stimulat- ing factor (GCSF) improves memory and neurobehavior in an amyloid-β induced experimental model of Alzheimer's disease. Pharmacol Biochem Behav. 2013;110:46-57. https:// doi. org/ 10. 1016/j. pbb. 2013. 05. 015. · DOI
- Jiskoot W, Crommelin D, editors. Methods for structural analysis of protein pharmaceuticals. Springer Science & Business Media. 2005. https:// link. sprin ger. com/ book/ 97809 71176 720? utm_ medium= refer ral& utm_ source= google_ books & utm_ campa ign=3_ pier05_ buy_ print & utm_ conte nt= en_ 08082 017
- Roessl U, Wiesbauer J, Leitgeb S, Birner-Gruenberger R, Nide- tzky B. Non-native aggregation of recombinant human granu- locyte-colony stimulating factor under simulated process stress conditions. Biotechnol J. 2012;7(8):1014-24. https:// doi. org/ 10. 1002/ biot. 20110 0436. · DOI
- Jenke D. Evaluation of the chemical compatibility of plastic contact materials and pharmaceutical products; safety consid- erations related to extractables and leachables. J Pharm Sci. 2007;96(10):2566-81. https:// doi. org/ 10. 1002/ jps. · DOI
- Nema S, Ludwig JD, editors. Pharmaceutical dosage forms: par- enteral medications, volume 3 set. CRC Press; 2010. https:// www. routl edge. com/ Pharm aceut ical-Dosage-Forms-Paren teral-Medic ations-Third-Editi on-3-Volume/ author/ p/ book/ 97814 82281 781.
- Zhang A, Singh S, Shirts M. Distinct aggregation mechanisms of monoclonal antibody under thermal and freeze/thaw-stresses revealed by hydrogen exchange. Pharm Res. 2012;29(1):236-50.
- Uversky V. Use of fast protein size-exclusion liquid chromatog- raphy to study the unfolding of proteins which denature through the molten globule. Biochemistry. 1993;32:13288-98.
- Lewis IR, Edwards H. Handbook of Raman spectroscopy: from the research laboratory to the process line. CRC Press; 2001. https:// www. routl edge. com/ Handb ook-of-Raman-Spect rosco py- From-the-Resea rch-Labor atory-to-the-Proce ss/ Lewis-Edwar ds/p/ book/ 97808 24705 57.
Cited by
Sorted by citations
Single-use solutions for PUPSIT: requirements, challenges, and solutions
Glenz, M., Eiermann, P., Manser, B., & Teschner, H. (2026) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-026-13847-5 · Cited by 1 · see citing works
- Authors
- Kushwah, V., Münzer, J., Feenstra, V., Mohr, S., & Paudel, A.
- Venue
- AAPS PharmSciTech
- Published
- 2022-08-24
- Volume
- 23
- Issue
- 7
- ISSN
- 1530-9932
- Cited by
- 5
- References
- 0
- Language
- en
- Funders
- Graz University of Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review