Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 247

The DOI matches its OpenAlex record.

A supersensitive immunofluorometric assay for rat luteinizing hormone

A.-M. Haavisto, Kim S. I. Pettersson, Matti Bergendahl, Antti H Perheentupa, Janet F. Roser, Ilpo Tapani Huhtaniemi · 1993 · Endocrinology

Abstract

We have developed an immunofluorometric assay (IFMA) for rat (r) LH, which is based on two monoclonal antibodies, one to bovine and the other to human LH. Signal detection occurs by time-resolved fluorescence evoked by a europium label (Delfia, Wallac). The method is fast in comparison to the standard RIA with the NIDDK reagents (4 h vs. 3 days). The sensitivity of the IFMA assay (0.75 pg/tube; NIDDK rLH RP-2) is over 30-fold higher than that of the NIDDK RIA (usual detection limit, 20-30 pg/tube). Using 25-microliters serum samples, the sensitivity of IFMA is 0.03 micrograms/liter; with 100-microliters samples, it is 0.0075 micrograms/liter. The cross-reactivity of the IFMA assay is 0.3% with rFSH, 3% with rTSH, and less than 0.05% with rGH, rPRL, and the rat alpha-subunit. A linear correlation between IFMA and RIA values is seen at serum levels above 0.4 micrograms/liter. Below this level, only IFMA is able to detect concentration differences between samples. In practice, this means that only IFMA is able to provide meaningful measurements of suppressed levels of serum LH. The correlation coefficient between IFMA and the mouse interstitial cell in vitro bioassay for LH in randomly selected rat pituitary homogenates was 0.93 (n = 47). The serum concentration of LH determined by IFMA is 0.57 +/- 0.10 micrograms/liter in intact adult male rats (mean +/- SEM; n = 12) and 0.41 +/- 0.10 micrograms/liter (n = 10) in randomly cycling females. The level in hypophysectomized rat serum is 0.035 +/- 0.0033 micrograms/liter (n = 8), if the limit of sensitivity (0.03 microgram/liter) is assigned to unmeasurable levels. One-week treatment of male rats with 2-cm Silastic implants containing testosterone suppressed serum LH, measured by IFMA, from 0.56 +/- 0.057 to 0.086 +/- 0.057 micrograms/liter (P < 0.01). The suppression of LH measured in the same samples by RIA was lower, from 0.73 +/- 0.057 to 0.44 +/- 0.048 micrograms/liter (P < 0.01). A 5-day starvation of intact male rats suppressed serum LH from 0.57 +/- 0.10 to 0.30 +/- 0.05 microgram/liter by IFMA (P < 0.01), whereas the decrease determined by RIA was not significant (0.80 +/- 0.07 vs. 0.66 +/- 0.13 micrograms/liter).(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1210/en.132.4.1687

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 247

Metadata

Authors
Haavisto, A.-M., Pettersson, K. S. I., Bergendahl, M., Perheentupa, A. H., Roser, J. F., & Huhtaniemi, I. T.
Venue
Endocrinology
Publisher
Oxford University Press
Published
1993-04-01
Volume
132
Issue
4
Pages
1687-1691
ISSN
0013-7227 (ISSN-L)
OpenAlex
W1986118516
Cited by
247
References
0
FWCI
7.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A supersensitive immunofluorometric assay for rat luteinizing hormone. https://app.cochat.ai/papers/10.1210/en.132.4.1687
The paper
Haavisto, A.-M., Pettersson, K. S. I., Bergendahl, M., Perheentupa, A. H., Roser, J. F., & Huhtaniemi, I. T. (1993). A supersensitive immunofluorometric assay for rat luteinizing hormone. Endocrinology. https://doi.org/10.1210/en.132.4.1687

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.