CoChat

Identification of Iopanoic Acid as Substrate of Type 1 Deiodinase by a Novel Nonradioactive Iodide-Release Assay

Renko, Kostja, Hoefig, Carolin S., Hiller, Franziska, Schomburg, Lutz, Köhrle, Josef · 2012 · Endocrinology
Cited by 80

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Enzymatic 5'- and 5-deiodination are key reactions for local and systemic activation and inactivation of iodothyronines and thyronamines. Expression of the three deiodinase (DIO) isoenzymes is regulated by a number of parameters, including thyroid status, genotype, micronutrient availability, and disease-related signaling. In addition, DIO are potential targets of pharmacological as well as environmentally derived substances, which might affect their enzymatic activity (endocrine disruptors). With the classical DIO activity assay, testing depends on the availability of radioactively labeled substrates (e.g. 125I-rT3) to monitor the release of radioactive iodide. Recently, liquid chromatography-tandem mass spectrometry was described as an alternative method apparently resolving this limitation. However, it has a high demand in technical equipment and analytical routine and is limited in sample number by considerable measuring time. We therefore combined the classical deiodination assay with an easily accessible photometric method taking advantage of the Sandell-Kolthoff reaction for measuring iodide release. In brief, iodine works as a catalyst within this redox reaction between Ce4+ and As3+ leading to an acceleration of destaining. Furthermore, the protocol was adapted to minimize handling effort and time consumption. Because this method is not dependent on radioactivity, it expands the substrate spectrum of the classical method. Suitability of this assay was tested with tissue samples from animal experiments (hepatic Dio1 activity in hypo- and hyperthyroid mice) and established DIO inhibitors. As a new but not unexpected finding, the alleged inhibitor iopanoic acid turned out to be a DIO substrate. This finding was confirmed by liquid chromatography-tandem mass spectrometry, and its potential clinical impact requires further studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/en.2011-1863

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 80

Metadata

Authors
Renko, K., Hoefig, C. S., Hiller, F., Schomburg, L., & Köhrle, J.
Venue
Endocrinology
Published
2012-03-20
Volume
153
Issue
5
Pages
2506-2513
ISSN
  • 0013-7227 (ISSN-L)
  • 1945-7170
OpenAlex
W1987580591
Cited by
80
References
5
FWCI
4.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Identification of Iopanoic Acid as Substrate of Type 1 Deiodinase by a Novel Nonradioactive Iodide-Release Assay. https://app.cochat.ai/papers/10.1210/en.2011-1863
The paper
Renko, K., Hoefig, C. S., Hiller, F., Schomburg, L., & Köhrle, J. (2012). Identification of Iopanoic Acid as Substrate of Type 1 Deiodinase by a Novel Nonradioactive Iodide-Release Assay. Endocrinology. https://doi.org/10.1210/en.2011-1863

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.