Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Cycle Detection: A Technique for Estimating the Frequency and Amplitude of Episodic Fluctuations inBlood Hormone and Substrate Concentrations*

CLIFTON, DONALD K., STEINER, ROBERT A. · 1983 · Endocrinology

Abstract

Investigation of episodic endocrine secretion has been hampered by inadequate analytical techniques for describing patterns of blood concentrations over time. Although standard time series methods, such as autocorrelation and power spectral analysis, are available, their use is limited to special cases in which rhythms are regular. To facilitate the analysis of our own episodic LH data, we have developed a process for determining the frequency and amplitude of both regular and irregular endocrine rhythms (signals) in the presence of high levels of random measurement errors (noise). This process, called cycle detection, engages an iterative, computerized procedure which scans data identifying sequential increases and decreases greater than an initial, preset threshold value. One complete cycle is defined as two increases greater than threshold separated by a decrease which is also greater than threshold. For an initial first pass estimate of frequency and amplitude, the threshold is set at 2.7 times the noise standard deviation. On the next pass, the threshold is readjusted, based on an empirically derived formula, and the data are scanned again. This process is repeated until the threshold reaches a stable value. We have tested the reliability of the cycle detection process by simulating irregular rhythm fluctuations of different frequencies, corrupted by various levels of noise and evaluating the signal characteristics with cycle detection analysis. These tests indicate that cycle detection provides excellent estimates of cycle frequency and amplitude, even with signal to noise ratios as low as 1.5. The ability of this process to analyze cyclic signals of almost any shape, with either regular or irregular rhythms, should make it a valuable tool in the hands of endocrine researchers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/endo-112-3-1057

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
CLIFTON, D. K., & STEINER, R. A.
Venue
Endocrinology
Published
1983-03
Volume
112
Issue
3
Pages
1057-1064
ISSN
  • 0013-7227 (ISSN-L)
  • 1945-7170
OpenAlex
W2038253016
Cited by
159
References
1
FWCI
8.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cycle Detection: A Technique for Estimating the Frequency and Amplitude of Episodic Fluctuations inBlood Hormone and Substrate Concentrations*. https://app.cochat.ai/papers/10.1210/endo-112-3-1057
The paper
CLIFTON, D. K., & STEINER, R. A. (1983). Cycle Detection: A Technique for Estimating the Frequency and Amplitude of Episodic Fluctuations inBlood Hormone and Substrate Concentrations*. Endocrinology. https://doi.org/10.1210/endo-112-3-1057

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.