CoChat

A Sensitive Biologic Assay for ACTH

LIPSCOMB, HARRY S., NELSON, DON H. · 1962 · Endocrinology
Cited by 128

The DOI matches its Crossref record.

Abstract

Fluorometric determination of corticosteroids in adrenal venous plasma of the acutely hypophysectomized rat has led to the development of 2 new techniques for the measurement of ACTH. The first, consisting of jugular injection of test material, with adrenal venous bleeding 5 minutes later, gives linearity of response to log doses of ACTH ranging from 0.05 to 1.0 milliunits (mU). The second method, consisting of retrograde injection of ACTH up the adrenal vein, with adrenal venous bleeding 90 seconds later, gives linearity of response over a range from 0.005 to 0.5 mU ACTH. The retrograde technique, while less precise, provides greater adrenal sensitivity to minute doses of ACTH than heretofore described. These methods are adaptable to the measurement of ACTH in biologic fluids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/endo-71-1-13

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 128

Metadata

Authors
LIPSCOMB, H. S., & NELSON, D. H.
Venue
Endocrinology
Published
1962-07
Volume
71
Issue
1
Pages
13-23
ISSN
  • 0013-7227 (ISSN-L)
  • 1945-7170
OpenAlex
W2066306806
Cited by
128
References
0
FWCI
5.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Sensitive Biologic Assay for ACTH. https://app.cochat.ai/papers/10.1210/endo-71-1-13
The paper
LIPSCOMB, H. S., & NELSON, D. H. (1962). A Sensitive Biologic Assay for ACTH. Endocrinology. https://doi.org/10.1210/endo-71-1-13

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.