The DOI matches its Crossref record.
A Sensitive Radioenzymatic Assay for Dopamine,Norepinephrine, and Epinephrine inPlasma and Tissue
Abstract
A double-isotope, radioenzymatic assay for measuring dopamine, norepinephrine, and epinephrine in one sample is described. The assay procedure includes incubation, solvent extraction, and thin-layer chromatography. Dopamine, norepinephrine, and epinephrine were incubated with catechol-O-methyl transferase (COMT) and [3H]S-acenosyl methionine ([3H]SAM) and were converted to the O-methylated tritiated derivatives: [3H]methoxytyramine, [3H]normetanephrine, and [3H]metanephrine, respectively. After several extraction steps the O-methylated products were purified by means of two-dimensional, thin-layer chromatography using silica gel. The thin-layer chromatographic system resulted complete separation of the three O-methylated compounds with an overlap of only 1-2%. The assay was linear from 0 to 5 ng for each catecholamine and had a sensitivity of 10-30 pg. The addition of large amounts of plasma reduced the activity of COMT, but increasing the magnesium concentration in the incubation mixture and the addition of EGTA to plasma samples improved the recoveries. Each sample was corrected for losses incurred during extraction and chromatography by using [14C]methoxytyramine, [14C]normetanephrine, and [14Ci1metanephrine that were added at the end of incubation. Several catechol compounds known to be O-methylated by COMT were examined for crossreactivity. Of the substances tested, only dihydroxyphenylalanine (DOPA) exhibited cross-reactivity. However, the apparent 30% cross-reactivity of DOPA with dopamine was due to the presence of decarboxylase activity in the COMT preparation. As little as 50 mul of trunk plasma from decapitated rats was sufficient for the determination of the three catecholamines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Simultaneous single isotope radioenzymatic assay of plasma norepinephrine, epinephrine and dopamine
Peuler, J. D., & Johnson, G. A. (1977) · Life Sciences · doi:10.1016/0024-3205(77)90070-4 · Cited by 1,899
KVETNANSKY, R., SUN, C. L., LAKE, C. R., THOA, N., TORDA, T., & KOPIN, I. J. (1978) · Endocrinology · doi:10.1210/endo-103-5-1868 · Cited by 292
Neuroendocrine Control of the Ovarian Cycle of the Rat
FREEMAN, M. (2006) · Knobil and Neill's Physiology of Reproduction · doi:10.1016/b978-012515400-0/50048-8 · Cited by 285
Plasma adrenaline, noradrenaline and dopamine in man and different animal species
Bühler, H. U., Prada, M. D., Haefely, W., & Picotti, G. B. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012235 · Cited by 269
The effect of moderate exercise on postprandial glucose homeostasis in NIDDM patients
Larsen, J. J. S., Dela, F., Kjær, M., & Galbo, H. (1997) · Diabetologia · doi:10.1007/s001250050699 · Cited by 183
Metadata
- Authors
- JONATHAN, N. B., & PORTER, J. C.
- Venue
- Endocrinology
- Publisher
- The Endocrine Society
- Published
- 1976-06
- Volume
- 98
- Issue
- 6
- Pages
- 1497-1507
- ISSN
- 0013-7227 (ISSN-L)
- 1945-7170
- OpenAlex
- W2025117833
- Cited by
- 197
- References
- 0
- FWCI
- 12.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Sensitive Radioenzymatic Assay for Dopamine,Norepinephrine, and Epinephrine inPlasma and Tissue. https://app.cochat.ai/papers/10.1210/endo-98-6-1497
- The paper
- JONATHAN, N. B., & PORTER, J. C. (1976). A Sensitive Radioenzymatic Assay for Dopamine,Norepinephrine, and Epinephrine inPlasma and Tissue. Endocrinology. https://doi.org/10.1210/endo-98-6-1497
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.