Bone Acquisition in Healthy Children and Adolescents: Comparisons of Dual-Energy X-Ray Absorptiometry and Computed Tomography Measures
The DOI matches its Crossref record.
Abstract
The effect that growth has on dual-energy x-ray absorptiometry (DXA) bone measurements is yet to be fully defined. The purpose of this study was to determine the best method for optimizing pediatric bone measurements using DXA. Height, weight, body mass index, skeletal age, and Tanner stage of sexual development were determined for 64 healthy boys and 60 healthy girls ages 6-17 yr. DXA of the lumbar vertebrae was performed to measure bone mineral content (BMC, grams) and areal bone mineral density (aBMD, grams per square centimeter), and geometric corrections were used to calculate volumetric bone mineral densities (vBMD): vBMD1 = aBMD/ radical(DXA-area) and vBMD2 = aBMD/bone height. Computed tomography (CT) imaging was performed to measure volumetric bone density (vBD) and vertebral volume (Vol) and to calculate CT-BMC = vBD * Vol. Linear regression was used to compare DXA-BMC vs. CT-BMC and CT vBD vs. DXA aBMD, vBMD1, and vBMD2. Multiple regression including the anthropometric and developmental parameters was also performed. DXA and CT BMC were highly correlated (r2= 0.94). However, DXA aBMD correlated more strongly with CT Vol (r2= 0.68) than with CT density (r2= 0.39), and calculation of DXA volumetric densities only slightly improved the density correlations (r2= 0.49 for vBMD1; r2= 0.55 for BMD2). The correlations for density were particularly poor for subjects in Tanner stages 1-3 (r2= 0.02 for aBMD; r2= 0.13 for vBMD1; r2= 0.27 for vBMD2). In contrast, multiple regression accounting for the anthropometric and developmental parameters greatly improved the agreement between the DXA and CT densities (r2= 0.91). These results suggest that DXA BMC is a more accurate and reliable measure than DXA BMD for assessing bone acquisition, particularly for prepubertal children and those in the early stages of sexual development. Use of DXA BMD would be reasonable if adjustments for body size, pubertal status, and skeletal maturity are made, but these additional assessments add significant complexity to the studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Weaver, C. M., Gordon, C. M., Janz, K. F., Kalkwarf, H. J., Lappe, J. M., Lewis, R., O’Karma, M., Wallace, T. C., & Zemel, B. S. (2016) · Osteoporosis International · doi:10.1007/s00198-015-3440-3 · Cited by 1,378
“Using spine QCT measures as a reference method, Wren and colleagues have shown that DXA BMC was a better measure to use in children (ages 6– 17 years), particularly in prepubertal children, than aBMD [62].”
MethodGordon, C. M., Bachrach, L. K., Carpenter, T. O., Crabtree, N., El-Hajj Fuleihan, G., Kutilek, S., Lorenc, R. S., Tosi, L. L., Ward, K. A., Ward, L. M., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.005 · Cited by 720
Rizzoli, R., Bianchi, M. L., Garabédian, M., McKay, H. A., & Moreno, L. A. (2010) · Bone · doi:10.1016/j.bone.2009.10.005 · Cited by 643
“This suggests that BMC may be a useful measure for assessing bone acquisition, particularly for pre-pubertal children and those in early stages of sexual development [38].”
BackgroundCrabtree, N. J., Arabi, A., Bachrach, L. K., Fewtrell, M., El-Hajj Fuleihan, G., Kecskemethy, H. H., Jaworski, M., & Gordon, C. M. (2014) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2014.01.003 · Cited by 552
Gordon, L. B., Kleinman, M. E., Miller, D. T., Neuberg, D. S., Giobbie-Hurder, A., Gerhard-Herman, M., Smoot, L. B., Gordon, C. M., Cleveland, R., Snyder, B. D., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202529109 · Cited by 375
Visceral Fat Is a Negative Predictor of Bone Density Measures in Obese Adolescent Girls
Russell, M., Mendes, N., Miller, K. K., Rosen, C. J., Lee, H., Klibanski, A., & Misra, M. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2009-1475 · Cited by 259
Pediatric DXA: technique and interpretation
Binkovitz, L. A., & Henwood, M. J. (2007) · Pediatric Radiology · doi:10.1007/s00247-006-0153-y · Cited by 210
“A different approach has been to not evaluate BMD at all, but to measure BMC only, because it is determined with greater accuracy and precision than BMD [53].”
BackgroundBone density in peripubertal boys with Autism Spectrum Disorders
Neumeyer, A. M., Gates, A., Ferrone, C., Lee, H., & Misra, M. (2013) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-012-1709-3 · Cited by 91
“To correct for height, we used measures of bone mineral apparent density (BMAD) for the spine (Wren et al. 2005).”
Method
Metadata
- Authors
- Wren, T. A. L., Liu, X., Pitukcheewanont, P., & Gilsanz, V.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 2005-04
- Volume
- 90
- Issue
- 4
- Pages
- 1925-1928
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2037068306
- Cited by
- 109
- References
- 0
- FWCI
- 13.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.