CoChat

Correlation among 25-Hydroxy-Vitamin D Assays

Binkley, N., Krueger, D., Gemar, D., Drezner, M. K. · 2008 · The Journal of Clinical Endocrinology & Metabolism
Cited by 110

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

CONTEXT: Measurement of circulating 25-hydroxy-vitamin D [25(OH)D]) is the accepted clinical indicator of vitamin D status. However, between-laboratory differences in measurement of this analyte exist, which may confound clinical care. OBJECTIVES: We investigated the current agreement of 25(OH)D measurement in clinical laboratories and explored the possibility that simple calibration would improve between-laboratory agreement. DESIGN AND PARTICIPANTS: Serum obtained from healthy volunteers (age 20-60 yr) and one "calibrator," selected to have a 25(OH)D value near 30 ng/ml, were sent for 25(OH)D measurement in four clinical laboratories (laboratories A-D) using HPLC, liquid chromatography tandem mass spectroscopy, and RIA methodologies. MAIN OUTCOME MEASURES: Serum 25(OH)D. Based upon self-report, the laboratory with the lowest interassay percent coefficient of variation was assigned as the reference to which the others were compared using linear regression and Bland-Altman analyses (Analyse-it; Analyse-it Software, Ltd., Leeds, UK). RESULTS: Good correlation was observed for 25(OH)D measurement between laboratory A and laboratories B-D (R(2) = 0.99, 0.81, and 0.95, respectively). Modest between-laboratory variation was noted; the mean bias ranged from 2.9-5.2 ng/ml. Consistent with a systematic offset, each value in laboratory B was higher than in laboratory A, and 89% of values from laboratories B-D were higher than laboratory A. The use of a single calibrator and correction factor reduced mean between-laboratory bias for laboratories B and D. CONCLUSIONS: Measurement of 25(OH)D by clinical laboratories yields similar results. The use of even a single calibrator will improve, but not resolve, between-laboratory variability. Based upon these data, in combination with reported within-individual variability, we recommend that clinicians aim for values greater than 30 ng/ml in their patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2007-2340

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 110

Metadata

Authors
Binkley, N., Krueger, D., Gemar, D., & Drezner, M. K.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2008-05
Volume
93
Issue
5
Pages
1804-1808
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2131516104
Cited by
110
References
2
FWCI
11.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correlation among 25-Hydroxy-Vitamin D Assays. https://app.cochat.ai/papers/10.1210/jc.2007-2340
The paper
Binkley, N., Krueger, D., Gemar, D., & Drezner, M. K. (2008). Correlation among 25-Hydroxy-Vitamin D Assays. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2007-2340

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.