OBJECTIVE: The aim was to formulate practice guidelines for determining settings where patients are most likely to benefit from the use of continuous glucose monitoring (CGM). PARTICIPANTS: The Endocrine Society appointed a Task Force of experts, a methodologist, and a medical writer. EVIDENCE: This evidence-based guideline was developed using the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) system to describe both the strength of recommendations and the quality of evidence. CONSENSUS PROCESS: One group meeting, several conference calls, and e-mail communications enabled consensus. Committees and members of The Endocrine Society, the Diabetes Technology Society, and the European Society of Endocrinology reviewed and commented on preliminary drafts of these guidelines. CONCLUSIONS: The Task Force evaluated three potential uses of CGM: 1) real-time CGM in adult hospital settings; 2) real-time CGM in children and adolescent outpatients; and 3) real-time CGM in adult outpatients. The Task Force used the best available data to develop evidence-based recommendations about where CGM can be beneficial in maintaining target levels of glycemia and limiting the risk of hypoglycemia. Both strength of recommendations and quality of evidence were accounted for in the guidelines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In critical care units, where the accuracy of POC meters is particularly crucial, their performance may be compromised by medications (vasopressors, acetaminophen), treatments (oxygen), and clinical states (hypotension, anemia) (17).”
From Hypoglycemia and Diabetes: A Report of a Workgroup of the American Diabetes Association and The Endocrine Society (2013) · cites this paper as [17]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Because the accuracy of CGMs, like POC meters, is negatively affected by multiple factors in hospitalized patients and they are calibrated with POC meters affected by those same factors, CGMs are not recommended for glycemic management in hospitalized patients at this time (17).”
From Hypoglycemia and Diabetes: A Report of a Workgroup of the American Diabetes Association and The Endocrine Society (2013) · cites this paper as [17]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In critical care units, where the accuracy of POC meters is particularly crucial, their performance may be compromised by medications (vasopressors, acetaminophen), treatments (oxygen), and clinical states (hypotension, anemia) (17).”
From Hypoglycemia and Diabetes: A Report of a Workgroup of the American Diabetes Association and The Endocrine Society (2013) · cites this paper as [17]
In the citing paper
“Because the accuracy of CGMs, like POC meters, is negatively affected by multiple factors in hospitalized patients and they are calibrated with POC meters affected by those same factors, CGMs are not recommended for glycemic management in hospitalized patients at this time (17).”
From Hypoglycemia and Diabetes: A Report of a Workgroup of the American Diabetes Association and The Endocrine Society (2013) · cites this paper as [17]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists are queued
They are fetched later and appear here then.
References 76 · Cited by 211
Metadata
- Authors
- Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H.
- Affiliations
- Mills Peninsula Health Services (US)
- Stanford Medicine (US)
- Aarhus University Hospital (DK)
- Yale University (US)
- Walter Reed National Military Medical Center (US)
- Joslin Diabetes Center (US)
- ORCID
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 2011-10
- Volume
- 96
- Issue
- 10
- Pages
- 2968-2979
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W1976351811
- Cited by
- 211
- References
- 76
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 6 · 2023: 4 · 2022: 10 · 2021: 8 · 2020: 9 · 2019: 8 · 2018: 23 · 2017: 15 · 2016: 15 · 2015: 24 · 2014: 27 · 2013: 27 · 2012: 23
- FWCI
- 21.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- The Journal of Clinical Endocrinology & Metabolism (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Funders
- European Society of Endocrinology
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, glycemic control, hypoglycemia prevention, diabetes management, hospitalized patients, children and adolescents, outpatients, real-time glucose monitoring, clinical guidelines
- MeSH terms
- Adolescent, Adult, Blood Glucose, Child, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Endocrinology, Hospitalization, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Monitoring, Physiologic, Outpatients, Evidence-Based Medicine, Consensus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Glucose Monitoring: An Endocrine Society Clinical Practice Guideline. https://app.cochat.ai/papers/10.1210/jc.2010-2756
- The paper
- Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011). Continuous Glucose Monitoring: An Endocrine Society Clinical Practice Guideline. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2010-2756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.