Cited by 84Clinical Laboratory Practices and Quality ControlThyroid Disorders and TreatmentsThyroid and Parathyroid Surgery

Macro-Thyrotropin: A Case Report and Review of Literature

Loh, Tze Ping, Kao, Shih Ling, Halsall, David J., Toh, Sue-Anne Ee Shiow, Chan, Edmund, Ho, Su Chin, Tai, E Shyong, Khoo, Chin Meng·2012·The Journal of Clinical Endocrinology & Metabolism

Abstract

CONTEXT: Isolated elevation of TSH in the absence of thyroid symptoms can be very rarely caused by a macromolecule formed between TSH and Ig (macro-TSH), confounding the interpretation of thyroid function test results. OBJECTIVE: We described the use of several commonly available laboratory-based approaches to investigate an isolated TSH elevation [232 mIU/liter; free T(4), 10 pmol/liter (reference interval, 10.0-23.0 pmol/liter), Vitros platform] in a clinically euthyroid elderly gentleman, which led to the diagnosis of macro-TSH. METHODS AND RESULTS: TSH concentration of the patient was significantly lower (122 mIU/liter) when measured on the Advia Centaur platform. Serial dilution of the patient's sample showed a nonlinear increase in TSH recovery at increasing dilution (nonlinearity). Polyethylene glycol precipitation and mixing the patient's sample with a hypothyroid patient sample showed reduced TSH recovery, suggesting the presence of a high molecular weight interfering substance and excess TSH binding capacity, respectively. Heterophile blocking tube studies and rheumatoid factors were negative. Gel filtration chromatography demonstrated a TSH peak fraction that approximated the molecular size of IgG; together with the excess TSH binding capacity, this indicated the presence of TSH-IgG macro-TSH. A review of 12 macro-TSH case reports showed that samples with macro-TSH produce over-recovery with dilution, return negative results on anti-animal and anti-heterophile blocking studies, and commonly have recovery of less than 20% when subjected to polyethylene glycol precipitation. CONCLUSION: Macro-TSH is an underrecognized laboratory interference. Routine laboratory techniques described above can help diagnose this rare entity. A close dialogue between the physician and the laboratory is important in approaching such cases.

Integrity signals

Registry

Crossref · 10.1210/jc.2011-3490

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 26 · Cited by 84

Authors
Loh, T. P., Kao, S. L., Halsall, D. J., Toh, S.-A. E. S., Chan, E., Ho, S. C., Tai, E. S., & Khoo, C. M.
Affiliations
  • Departments of Laboratory Medicine (T.P.L.), Singapore 119074
  • National University Hospital (SG)
  • Addenbrooke's Hospital (GB)
  • National University of Singapore (SG)
  • Mount Elizabeth Hospital (SG)
Corresponding author
Loh, Tze Ping
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2012-06-01
Volume
97
Issue
6
Pages
1823-1828
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W1983235235
Cited by
84
References
26
Citations by year
2026: 1 · 2025: 3 · 2024: 7 · 2023: 13 · 2022: 6 · 2021: 5 · 2020: 2 · 2019: 7 · 2018: 7 · 2017: 3 · 2016: 11 · 2015: 4 · 2014: 3 · 2013: 9 · 2012: 3
FWCI
4.07
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of Clinical Endocrinology & Metabolism (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
  • Health Sciences › Medicine › Surgery › Thyroid and Parathyroid Surgery
Keywords
laboratory test interference, thyroid function tests, polyethylene glycol precipitation, size exclusion chromatography, euthyroid patients
MeSH terms
False Positive Reactions, Humans, Hypothyroidism, Immunoglobulin G, Male, Middle Aged, Molecular Weight, Thyroid Function Tests, Thyrotropin, Thyroxine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review