Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record.

Trabecular Bone Score (TBS)—A Novel Method to Evaluate Bone Microarchitectural Texture in Patients With Primary Hyperparathyroidism

Open access
Silva, Barbara Campolina, Boutroy, Stephanie, Zhang, Chiyuan, McMahon, Donald Jay, Zhou, Bin, Wang, Ji, Udesky, Julia, Cremers, Serge, Sarquis, Marta, Guo, Xiang-Dong Edward, Hans, Didier, Bilezikian, John Paul · 2013 · The Journal of Clinical Endocrinology & Metabolism

Abstract

CONTEXT: In the milder form of primary hyperparathyroidism (PHPT), cancellous bone, represented by areal bone mineral density at the lumbar spine by dual-energy x-ray absorptiometry (DXA), is preserved. This finding is in contrast to high-resolution peripheral quantitative computed tomography (HRpQCT) results of abnormal trabecular microstructure and epidemiological evidence for increased overall fracture risk in PHPT. Because DXA does not directly measure trabecular bone and HRpQCT is not widely available, we used trabecular bone score (TBS), a novel gray-level textural analysis applied to spine DXA images, to estimate indirectly trabecular microarchitecture. OBJECTIVE: The purpose of this study was to assess TBS from spine DXA images in relation to HRpQCT indices and bone stiffness in radius and tibia in PHPT. DESIGN AND SETTING: This was a cross-sectional study conducted in a referral center. PATIENTS: Participants were 22 postmenopausal women with PHPT. MAIN OUTCOME MEASURES: Outcomes measured were areal bone mineral density by DXA, TBS indices derived from DXA images, HRpQCT standard measures, and bone stiffness assessed by finite element analysis at distal radius and tibia. RESULTS: TBS in PHPT was low at 1.24, representing abnormal trabecular microstructure (normal ≥1.35). TBS was correlated with whole bone stiffness and all HRpQCT indices, except for trabecular thickness and trabecular stiffness at the radius. At the tibia, correlations were observed between TBS and volumetric densities, cortical thickness, trabecular bone volume, and whole bone stiffness. TBS correlated with all indices of trabecular microarchitecture, except trabecular thickness, after adjustment for body weight. CONCLUSION: TBS, a measurement technology readily available by DXA, shows promise in the clinical assessment of trabecular microstructure in PHPT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2012-4255

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 201

Metadata

Authors
Silva, B. C., Boutroy, S., Zhang, C., McMahon, D. J., Zhou, B., Wang, J., Udesky, J., Cremers, S., Sarquis, M., Guo, X.-D. E., Hans, D., & Bilezikian, J. P.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2013-05-01
Volume
98
Issue
5
Pages
1963-1970
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2171520628
Cited by
201
References
0
FWCI
20.32
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Trabecular Bone Score (TBS)—A Novel Method to Evaluate Bone Microarchitectural Texture in Patients With Primary Hyperparathyroidism. https://app.cochat.ai/papers/10.1210/jc.2012-4255
The paper
Silva, B. C., Boutroy, S., Zhang, C., McMahon, D. J., Zhou, B., Wang, J., Udesky, J., Cremers, S., Sarquis, M., Guo, X.-D. E., Hans, D., & Bilezikian, J. P. (2013). Trabecular Bone Score (TBS)—A Novel Method to Evaluate Bone Microarchitectural Texture in Patients With Primary Hyperparathyroidism. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2012-4255

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.