Label-free Intraoperative Parathyroid Localization With Near-Infrared Autofluorescence Imaging
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
CONTEXT: The inability to accurately localize the parathyroid glands during parathyroidectomy and thyroidectomy procedures can prevent patients from achieving postoperative normocalcemia. There is a critical need for an improved intraoperative method for real-time parathyroid identification. OBJECTIVE: The objective of the study was to test the accuracy of a real-time, label-free technique that uses near-infrared (NIR) autofluorescence imaging to localize the parathyroid. SETTING: The study was conducted at the Vanderbilt University endocrine surgery center. SUBJECTS AND METHODS: Patients undergoing parathyroidectomy and/or thyroidectomy were included in this study. To validate the intrinsic fluorescence signal in parathyroid, point measurements from 110 patients were collected using NIR fluorescence spectroscopy. Fluorescence imaging was performed on 6 patients. Imaging contrast is based on a previously unreported intrinsic NIR fluorophore in the parathyroid gland. The accuracy of fluorescence imaging was analyzed in comparison with visual assessment and histological findings. MAIN OUTCOME MEASURE: The detection rate of parathyroid glands was measured. RESULTS: The parathyroid glands in 100% of patients measured with fluorescence imaging were successfully detected in real time. Fluorescence images consistently showed 2.4 to 8.5 times higher emission intensity from the parathyroid than surrounding tissue. Histological validation confirmed that the high intrinsic fluorescence signal in the parathyroid gland can be used to localize the parathyroid gland regardless of disease state. CONCLUSION: NIR fluorescence imaging represents a highly sensitive, real-time, label-free tool for parathyroid localization during surgery. The elegance and effectiveness of NIR autofluorescence imaging of the parathyroid gland makes it highly attractive for clinical application in endocrine surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extracellular Calcium Sensing and Extracellular Calcium Signaling
Brown, E. M., & MacLeod, R. J. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.1.239 · Cited by 1,388
The Importance of Surgeon Experience for Clinical and Economic Outcomes From Thyroidectomy
Sosa, J. A., Bowman, H. M., Tielsch, J. M., Powe, N. R., Gordon, T. A., & Udelsman, R. (1998) · Annals of Surgery · doi:10.1097/00000658-199809000-00005 · Cited by 1,118
Gogusev, J., Duchambon, P., Hory, B., Giovannini, M., Goureau, Y., Sarfati, E., & Drüeke, T. B. (1997) · Kidney International · doi:10.1038/ki.1997.41 · Cited by 493 · cited 1×
“Calcium-sensing receptors are known to be downregulated in patients with hyperparathyroidism (30), which is consistent with the lower fluorescence intensity measured in the parathyroid glands of patients with hyperparathyroidism.”
BackgroundSurgeon volume as a predictor of outcomes in inpatient and outpatient endocrine surgery
Stavrakis, A. I., Ituarte, P. H. G., Ko, C. Y., & Yeh, M. W. (2007) · Surgery · doi:10.1016/j.surg.2007.09.003 · Cited by 371 · cited 1×
“It has been shown that the complication rate in thyroid and parathyroid surgery is inversely proportional to the experience of the operating surgeon (25, 26), indicating that a tool for intraoperative parathyroid localization has the greatest potential for impact in the hands of less experienced surgeons.”
BackgroundA review of imaging techniques for systems biology
Kherlopian, A. R., Song, T., Duan, Q., Neimark, M. A., Po, M. J., Gohagan, J. K., & Laine, A. F. (2008) · BMC Systems Biology · doi:10.1186/1752-0509-2-74 · Cited by 310
Complications after total thyroidectomy
Christou, N., & Mathonnet, M. (2013) · Journal of Visceral Surgery · doi:10.1016/j.jviscsurg.2013.04.003 · Cited by 308
Localization of the extracellular Ca2+/polyvalent cation-sensing protein in rat kidney
Riccardi, D., Hall, A. E., Chattopadhyay, N., Xu, J. Z., Brown, E. M., & Hebert, S. C. (1998) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.1998.274.3.f611 · Cited by 307
Identification and localization of extracellular Ca2+-sensing receptor in rat intestine
Chattopadhyay, N., Cheng, I., Rogers, K., Riccardi, D., Hall, A., Diaz, R., Hebert, S. C., Soybel, D. I., & Brown, E. M. (1998) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.1998.274.1.g122 · Cited by 220
Sakorafas, G. H., Stafyla, V., Bramis, C., Kotsifopoulos, N., Kolettis, T., & Kassaras, G. (2005) · World Journal of Surgery · doi:10.1007/s00268-005-0032-y · Cited by 172
Real-time, near-infrared, fluorescence-guided identification of the ureters using methylene blue
Matsui, A., Tanaka, E., Choi, H. S., Kianzad, V., Gioux, S., Lomnes, S. J., & Frangioni, J. V. (2010) · Surgery · doi:10.1016/j.surg.2009.12.003 · Cited by 157
Surgical complications after thyroid surgery performed in a cancer hospital
Filho, J. G., & Kowalski, L. P. (2005) · Otolaryngology · doi:10.1016/j.otohns.2004.09.028 · Cited by 148
Verdicts on malpractice claims after thyroid surgery: Emerging trends and future directions
Dralle, H., Lorenz, K., & Machens, A. (2012) · Head & Neck · doi:10.1002/hed.21970 · Cited by 123 · cited 1×
“Insufficient parathyroid identification during cervical endocrine surgery can irreversibly damage the body’s calcium regulation, which has led it to become one of the principal causes of surgical malpractice litigation (24).”
BackgroundHadjipanayis, C. G., Jiang, H., Roberts, D. W., & Yang, L. P. H. (2011) · Seminars in Oncology · doi:10.1053/j.seminoncol.2010.11.008 · Cited by 106
Prosst, R. L., Weiß, J., Hupp, L., Willeke, F., & Post, S. (2010) · World Journal of Surgery · doi:10.1007/s00268-010-0621-2 · Cited by 63
Risk factors of incidental parathyroidectomy after thyroidectomy for benign thyroid disorders
Erbil, Y., Barbaros, U., Özbey, N., et al. (2008) · International Journal of Surgery · doi:10.1016/j.ijsu.2008.10.012 · Cited by 47
Cited by
Benmiloud, F., Godiris-Petit, G., Gras, R., Gillot, J.-C., Turrin, N., Penaranda, G., Noullet, S., Chéreau, N., Gaudart, J., Chiche, L., et al. (2020) · JAMA Surgery · doi:10.1001/jamasurg.2019.4613 · Cited by 214
Metadata
- Authors
- McWade, M. A., Paras, C., White, L. M., Phay, J. E., Solórzano, C. C., Broome, J. T., & Mahadevan-Jansen, A.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 2014-12
- Volume
- 99
- Issue
- 12
- Pages
- 4574-4580
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2157478648
- Cited by
- 182
- References
- 15
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.