CoChat

A comparison of lateral versus anterior-posterior spine dual energy x- ray absorptiometry for the diagnosis of osteopenia

Finkelstein, J. S. · 1994 · Journal of Clinical Endocrinology & Metabolism
Cited by 122

The DOI matches its Crossref record.

Abstract

Because bone mineral density (BMD) measurements at various sites differ in the relative amounts of cortical and trabecular bone that they assess, they also differ in their sensitivity for detecting osteopenia. Lateral spine dual energy x-ray absorptiometry (DXA) allows measurement of BMD of the vertebral bodies, which contain mainly trabecular bone, without contribution from the posterior vertebral elements, which are rich in cortical bone. Thus, we hypothesized that lateral spine DXA would detect osteopenia more frequently than anterior-posterior (AP) spine DXA. To assess the ability of DXA to estimate trabecular bone mass, we compared AP and lateral DXA spine measurements with trabecular bone measurements by quantitative computed tomography (QCT) in 58 patients. We then compared AP vs. lateral spine DXA measurements in 1) 300 women referred for routine bone densitometry, 2) 30 glucocorticoid-treated women, and 3) 44 women with vertebral compression fractures. To compare short term reproducibility, we performed repeat AP and lateral DXA scans in 50 women. The association between QCT and DXA measurements was stronger when DXA measurements were made in the lateral (r = 0.784) or midlateral (r = 0.823) projection than in the AP (r = 0.571) projection. The association of BMD with age was stronger when DXA measurements were made in the lateral (r = 0.536) or midlateral (r = 0.536) projection than in the AP (r = 0.382) projection. The declines in BMD with age for AP, lateral, and midlateral DXA measurements were 0.48%, 0.60%, and 0.88%/yr, respectively. In the women referred for routine densitometry, lateral DXA measurements were significantly (P < 0.05) more abnormal than AP measurements compared with those in young women. This was also true in the women treated with glucocorticoids and women with vertebral compression fractures. Lateral DXA often detected osteopenia in patients whose AP DXA was normal. The 95% confidence limits for changes in BMD attributable to measurement error for AP, lateral, and midlateral DXA were 0.027, 0.038, and 0.057 g/cm2, respectively. These results indicate that lateral DXA measurements identify patients with osteopenia more often than AP DXA measurements, probably because lateral DXA more accurately estimates trabecular bone mass. Short term reproducibility of lateral DXA is nearly as good as that for AP DXA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.78.3.724

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 122

Metadata

Authors
Finkelstein, J. S.
Venue
Journal of Clinical Endocrinology & Metabolism
Published
1994-03-01
Volume
78
Issue
3
Pages
724-730
ISSN
0021-972X (ISSN-L)
OpenAlex
W2037351893
Cited by
122
References
0
FWCI
9.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of lateral versus anterior-posterior spine dual energy x- ray absorptiometry for the diagnosis of osteopenia. https://app.cochat.ai/papers/10.1210/jc.78.3.724
The paper
Finkelstein, J. S. (1994). A comparison of lateral versus anterior-posterior spine dual energy x- ray absorptiometry for the diagnosis of osteopenia. Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.78.3.724

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.