CoChat

Comparison of second and third generation methods for measurement of serum thyrotropin in patients with overt hyperthyroidism, patients receiving thyroxine therapy, and those with nonthyroidal illness

Franklyn, J. A. · 1994 · Journal of Clinical Endocrinology & Metabolism
Cited by 79

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

We compared serum TSH results determined in second and third generation assays in patients with thyroid disease and nonthyroidal illnesses (NTIs) to evaluate the usefulness of the more sensitive assay. We studied 19 subjects with untreated hyperthyroidism, 12 hyperthyroid subjects sampled at 4-week intervals after beginning carbimazole, 153 subjects receiving T4 replacement, and 300 hospital in-patients with a variety of NTIs. Serum TSH was measured, using a second generation immunometric method, together with free T4 and free T3. Samples with subnormal TSH (< 0.5 mU/L) were reassayed, using a more sensitive chemiluminescent immunometric method. Both assays revealed undetectable serum TSH levels in 18 of 19 overtly hyperthyroid patients. Undetectable TSH values (in both assays) were found in 30 of 33 patients with low serum TSH levels who were receiving treatment for hyperthyroidism, in association with normal thyroid hormone levels in 11. Undetectable TSH was evident in both patients receiving T4 and those with NTI, but use of the more sensitive assay led to a reduction in the number of subjects with undetectable TSH compared with the second generation results (T4-treated, 55 vs. 77 cases; NTI, 13 vs. 19 cases). There was a significant correlation between serum TSH and free T4 in the whole group on T4 (P < 0.001) and in those receiving T4 with low TSH (r = -0.33; P < 0.05); no significant correlation was evident in subjects with low serum TSH levels associated with NTI. An improvement in assay sensitivity led to a reduction in the number of patients being treated with T4 or with NTI in whom serum TSH was undetectable and, hence, an increase in those in whom overt hyperthyroidism could be excluded. Undetectable TSH results, even in a third generation assay, are not diagnostic of overt hyperthyroidism, but are also found in subjects with treated thyroid disease and NTI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.78.6.1368

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
Franklyn, J. A.
Venue
Journal of Clinical Endocrinology & Metabolism
Published
1994-06-01
Volume
78
Issue
6
Pages
1368-1371
ISSN
0021-972X (ISSN-L)
OpenAlex
W2071149178
Cited by
79
References
2
FWCI
6.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.