The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Statistical Quality Control of Radioimmunoassays1
Abstract
Radioimmunoassay (RIA) and competitive protein binding (CPB) assays provide dose response curves which show severe nonlinearity and the residual (error) variance is non-uniform and not normally distributed. Accordingly, several classic “least squares” statistical procedures commonly used for bioassay data are not directly applicable. Linearization may be obtained by the use of the logit transformation, but this increases non-uniformity of variance. We have utilized an empirical quality control system in order to obtain estimates of the stability, precision and reproducibility of the radioimmunoassays and CPB assays. These methods provide sequential monitoring of the performance of the assays, and permit the determination of valid estimates of confidence limits on potency estimates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Statistical Analysis.
Latshaw, V. V., Dixon, W. J., & Massey, F. J. (1957) · The American Mathematical Monthly · doi:10.2307/2309989 · Cited by 5,072
Quality Control and Industrial Statistics.
Lave, R. E., & Duncan, A. J. (1967) · Journal of the American Statistical Association · doi:10.2307/2282940 · Cited by 1,001
Statistical Method in Biological Assay.
Barton, D. E., & Finney, D. J. (1966) · Biometrika · doi:10.2307/2334099 · Cited by 813
Cited by
Overexpression of Metallothionein Confers Resistance to Anticancer Drugs
Kelley, S. L., Basu, A., Teicher, B. A., Hacker, M. P., Hamer, D. H., & Lazo, J. S. (1988) · Science · doi:10.1126/science.3175622 · Cited by 601
The five-parameter logistic: A characterization and comparison with the four-parameter logistic
Gottschalk, P. G., & Dunn, J. R. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.04.035 · Cited by 449
Radioimmunoassay for Measurement of Thyroglobulin in Human Serum
Van Herle, A. J., Uller, R. P., Matthews, N. L., & Brown, J. (1973) · Journal of Clinical Investigation · doi:10.1172/jci107303 · Cited by 397
The renin system: Variations in man measured by radioimmunoassay or bioassay
Sealey, J. E., Gerten-Banes, J., & Laragh, J. H. (1972) · Kidney International · doi:10.1038/ki.1972.34 · Cited by 382
Pituitary and Gonadal Hormones in Women during Spontaneous and Induced Ovulatory Cycles
ROSS, G. T., CARGILLE, C. M., LIPSETT, M. B., RAYFORD, P. L., MARSHALL, J. R., STROTT, C. A., & RODBARD, D. (1970) · Proceedings of the 1969 Laurentian Hormone Conference · doi:10.1016/b978-0-12-571126-5.50005-4 · Cited by 373
Self-citation
Metadata
- Authors
- RODBARD, D., RAYFORD, P. L., COOPER, J. A., & ROSS, G. T.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 1968-10
- Volume
- 28
- Issue
- 10
- Pages
- 1412-1418
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2202263696
- Cited by
- 322
- References
- 3
- FWCI
- 10.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Statistical Quality Control of Radioimmunoassays1. https://app.cochat.ai/papers/10.1210/jcem-28-10-1412
- The paper
- RODBARD, D., RAYFORD, P. L., COOPER, J. A., & ROSS, G. T. (1968). Statistical Quality Control of Radioimmunoassays1. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem-28-10-1412
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.