The DOI matches its Crossref record.
Radioimmunoassay Measurement of Arginine Vasopressin in Serum: Development and Application
Abstract
The present report describes the development of a sensitive and specific radioimmunoassay system (RIA) for measurement of arginine vasopressin (AVP) in serum or plasma. The RIA has a sensitivity of 0.3–0.5 μU/ml and employs an extraction procedure utilizing the diatomaceous earth Bentonite. This procedure also permits AVP measurements in maternal and fetal blood in the presence of elevated levels of vasopressinase. Serum AVP concentrations were measured in normal adult subjects in various states of hydration and in selected patients with abnormalities of AVP metabolism. The RIA results are in good agreement with previously reported bioassay results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Regulation of Vasopressin Function in Health and Disease
ROBERTSON, G. L. (1977) · Proceedings of the 1976 Laurentian Hormone Conference · doi:10.1016/b978-0-12-571133-3.50015-5 · Cited by 373
Evidence supporting a role for endogenous vasopressin in natural suppression of fever in the sheep.
Cooper, K. E., Kasting, N. W., Lederis, K., & Veale, W. L. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012953 · Cited by 252
Vasopressin, oxytocin and neurophysins in the human brain and spinal cord
Jenkins, J. S., Ang, V. T. Y., Hawthorn, J., Rossor, M. N., & Iversen, L. L. (1984) · Brain Research · doi:10.1016/0006-8993(84)90656-5 · Cited by 126
THE EFFECT OF VASOPRESSIN INFUSION ON GLUCOSE METABOLISM IN MAN
SPRUCE, B. A., MCCULLOCH, A. J., BURD, J., ØRSKOV, H., HEATON, A., BAYLIS, P. H., & ALBERTI, K. G. M. M. (1985) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1985.tb00145.x · Cited by 114
The milk ejection reflex in the pig
Ellendorff, F., Forsling, M. L., & Poulain, D. A. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014470 · Cited by 116
Metadata
- Authors
- SKOWSKY, W. R., ROSENBLOOM, A. A., & FISHER, D. A.
- Venue
- The Journal of Clinical Endocrinology & Metabolism
- Publisher
- The Endocrine Society
- Published
- 1974-02
- Volume
- 38
- Issue
- 2
- Pages
- 278-287
- ISSN
- 0021-972X (ISSN-L)
- 1945-7197
- OpenAlex
- W2070483306
- Cited by
- 306
- References
- 0
- FWCI
- 22.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radioimmunoassay Measurement of Arginine Vasopressin in Serum: Development and Application. https://app.cochat.ai/papers/10.1210/jcem-38-2-278
- The paper
- SKOWSKY, W. R., ROSENBLOOM, A. A., & FISHER, D. A. (1974). Radioimmunoassay Measurement of Arginine Vasopressin in Serum: Development and Application. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem-38-2-278
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.