Cited by 71Stress Responses and CortisolAdrenal Hormones and DisordersCircadian rhythm and melatonin

Intensive venous sampling paradigms disclose high frequency adrenocorticotropin release episodes in normal men

IRANMANESH, ALI, LIZARRALDE, GERMAN, SHORT, DELMAR, VELDHUIS, JOHANNES D.·1990·The Journal of Clinical Endocrinology & Metabolism

Abstract

Recent studies in the rat and rhesus monkey have disclosed apparently high frequency in vivo ACTH release episodes. While the circadian pattern of plasma ACTH concentrations has been known for many years, the exact frequency of ultradian pulsatile ACTH release in man is not clear, due in part to variable intensities of blood-sampling schedules and the limited availability of sensitive ACTH assays. In this study we used a new sensitive and specific immunoradiometric assay to measure plasma ACTH concentrations in blood sampled at 1) 2-min intervals for 3 h, followed by 4-min intervals for 4 more h in six men; and 2) 10-min intervals for 24 h in eight other men. An objective peak detection algorithm (Cluster) and cosinor analyses were used to assess the episodic pulsatility and circadian rhythmicity of ACTH. Comparisons were made among the 2 min (3 h), 4, 8, and 12 min (7 h), and 10 min (24 h) time series. Mean ACTH interpulse intervals were significantly different among the five sampling groups (P less than 0.00001). Sampling every 2 min yielded a mean ACTH interpulse interval of 18 min, which was significantly shorter than the mean interpulse intervals of 35, 53, 52, and 73 min resulting, respectively, from sampling every 4, 8, 10, and 12 min (P less than 0.05). In contrast, maximal peak ACTH amplitudes (picomoles per L or percent increase) did not vary as a function of sampling frequency. The 24-h plasma ACTH concentration time series showed significant diurnal variation, with a mean circadian amplitude of 0.95 +/- 0.15 pmol/L occurring at 1008 h (+/- 25 min). Cosinor analysis of various ACTH pulse parameters deduced from the 24-h time series revealed significant circadian rhythmicity in the ACTH peak maxima (P less than 0.05), peak increments (P less than 0.05), and prepeak nadir (P less than 0.05) concentrations, but not in ACTH interpulse intervals. We conclude that in men, 1) intensive sampling at 2-min intervals unmasks high frequency ACTH release episodes that cannot be detected at conventional sampling rates; and 2) ACTH peak amplitude, but not frequency, varies significantly during the course of circadian changes in the plasma ACTH concentrations.

Integrity signals

Registry

Crossref · 10.1210/jcem-71-5-1276

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 18 · Cited by 71

Authors
IRANMANESH, A., LIZARRALDE, G., SHORT, D., & VELDHUIS, J. D.
Affiliations
University of Virginia Health System (US)
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
1990-11
Volume
71
Issue
5
Pages
1276-1283
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2116977020
Cited by
71
References
18
Citations by year
2025: 1 · 2024: 1 · 2023: 1 · 2021: 2 · 2020: 1 · 2018: 1 · 2017: 1 · 2015: 2 · 2014: 4 · 2013: 3 · 2012: 1
FWCI
1.35
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of Clinical Endocrinology & Metabolism (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • University of Virginia
  • National Institutes of Health (5k04hd000634-02, 5p60am022125-08)
  • National Center for Research Resources (RR 00847, M01RR000847)
  • NIH Clinical Center
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (1-K04-HD-00634)
Topics
  • Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
Keywords
sampling frequency, circadian rhythm, interpulse interval, immunoradiometric assay, cosinor analysis, normal men, diurnal variation, hypothalamic-pituitary-adrenal axis, ACTH secretion
MeSH terms
Adrenocorticotropic Hormone, Adult, Blood Specimen Collection, Catheters, Indwelling, Circadian Rhythm, Humans, Male, Middle Aged, Veins

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review