CoChat

Cortisol Production Rates in Subjects with Suspected Cushing’s Syndrome: Assessment by Stable Isotope Dilution Methodology and Comparison to Other Diagnostic Methods1

Samuels, M. H., Brandon, D. D., Isabelle, L. M., Cook, D. M., Graham, K. E., Purnell, J. Q., Loriaux, D. L. · 2000 · The Journal of Clinical Endocrinology & Metabolism
Cited by 14

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

It can be difficult to establish the diagnosis of Cushing's Syndrome (CS) in patients with mild or nonspecific clinical and biochemical findings, because available diagnostic tests have limited predictive values. We hypothesized that measurement of 24-h cortisol production rates (CPRs) might be a more sensitive indicator of CS in such patients. We measured CPRs in 28 patients with suspected CS (but equivocal biochemical findings) and in 22 healthy control subjects, by infusing tracer amounts of deuterated cortisol, with simultaneous measurements of 24-h urine free cortisol (UFC) levels; and we frequently sampled serum cortisol levels. CPRs were calculated from the ratio of isotopic enrichment to isotopic dilution of cortisol measured by gas chromatography-negative ion chemical ionization mass spectrometry. Nine of the patients proved to have CS by surgery (CS-Yes), whereas 19 patients were determined not to have CS by biochemical testing (CS-No). Mean 24-h UFCs, nocturnal serum cortisol levels, and CPRs were higher in CS-Yes, compared with CS-No and normal subjects. However, one CS-Yes patient had a normal 24-h UFC, two had normal nocturnal serum cortisol levels, and two had normal 24-h CPRs. There was extensive overlap in all of the biochemical parameters between the CS-Yes and the CS-No groups. Thus, measurement of CPR does not seem to offer any diagnostic advantage over available tests for the diagnosis of CS. Patients with proven CS can have normal UFC levels, normal CPRs, or normal nocturnal cortisol levels, whereas patients not thought to have CS may have elevated levels of any one or more these parameters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jcem.85.1.6259

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 14

Metadata

Authors
Samuels, M. H., Brandon, D. D., Isabelle, L. M., Cook, D. M., Graham, K. E., Purnell, J. Q., & Loriaux, D. L.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2000-01-01
Volume
85
Issue
1
Pages
22-28
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2002145535
Cited by
14
References
3
FWCI
0.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.