CoChat

A New Recombinant Cell Bioassay for Ultrasensitive Determination of Serum Estrogenic Bioactivity in Children

Open access
Paris, F. · 2002 · Journal of Clinical Endocrinology & Metabolism
Cited by 77

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The evaluation of estrogenic status is necessary for many physiological and pathological conditions in pediatric as well as adult endocrinology. Because current immunoassays exclusively measure E2--and with a sensitivity that is insufficient for prepubertal children--we developed a new recombinant cell bioassay for ultrasensitive determination of serum estrogenic bioactivity. This assay is based on human uterine cervix carcinoma cells, HeLa cells, that do not naturally express E2 receptor. These cells were transfected with plasmids encoding the human ERalpha or beta, along with an estrogen-responsive promoter fused to the luciferase gene, and called HELNalpha and HELNbeta for HeLa estrogen-responsive element luciferase neomycin alpha and beta. HELNalpha and HELNbeta are able to respond to estrogens and various compounds having estrogenic activity but, because of the importance of ERalpha in the reproductive function, we chose to work with the HELNalpha cell line. The luciferase activity we obtained was compared with an E2 standard curve specific for each serum sample and established with stripped serum. The estrogenic bioactivity was expressed in picograms of E2 equivalents, and the detection limit was < 1 pg x ml(-1) E2 equivalents. The intra and interassay error was lower than 10% and 20%, respectively. We measured estrogenic bioactivity in 18 normal prepubertal boys (age = 9.7 +/- 2.4 yr), 18 normal prepubertal girls (age = 9.2 +/- 1.7 yr) and 18 normal pubertal girls (age = 13.6 +/- 1.8 yr). The estrogenic bioactivity in the prepubertal girls was significantly higher than in the boys, i.e. 3.53 +/- 2.23 pg x ml(-1) vs. 1.44 +/- 0.87 pg x ml(-1) (P < 0.01). A significant difference was found between the pre- and pubertal girls, i.e. 3.53 +/- 2.23 pg x ml(-1) vs. 26.77 +/- 18.32 pg x ml(-1) (P < 0.01). This ultrasensitive bioassay measures total estrogenic bioactivity of serum with very high sensitivity. It has numerous potential applications in pediatric and adult endocrinology. In addition, this assay may help to evaluate excess estrogenic activity related to aromatase overexpression or contamination by environmental chemicals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.87.2.791

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 77

Metadata

Authors
Paris, F.
Venue
Journal of Clinical Endocrinology & Metabolism
Published
2002-02-01
Volume
87
Issue
2
Pages
791-797
ISSN
0021-972X (ISSN-L)
OpenAlex
W1997539143
Cited by
77
References
1
FWCI
2.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A New Recombinant Cell Bioassay for Ultrasensitive Determination of Serum Estrogenic Bioactivity in Children. https://app.cochat.ai/papers/10.1210/jc.87.2.791
The paper
Paris, F. (2002). A New Recombinant Cell Bioassay for Ultrasensitive Determination of Serum Estrogenic Bioactivity in Children. Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.87.2.791

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.