Cited by 6Diabetes Management and ResearchDiabetes and associated disordersPancreatic function and diabetes

Paediatric society and hyperinsulinism charity national surveys on cgm access for patients with recurrent hypoglycaemia

Open access
Ng, Sze May, Dearman, Sarah, Fisher, Mark, Mushtaq, Talat, Randell, Tabitha·2023·Journal of the Endocrine Society

Abstract

Context: Recurrent hypoglycemia can result in significant neurological impairments in children and continuous glucose monitoring (CGM) technology has been shown to reduce recurrent hypoglycemia in conditions such as type 1 diabetes. In the United Kingdom, CGM devices are currently only recommended by the National Institute of Clinical Excellence (NICE) for patients with diabetes and not for other diagnoses. Objective: To examine access to CGM technology for children and young people with recurrent hypoglycemia in the United Kingdom. Methods: In 2021, the British Society of Paediatric Endocrinology and Diabetes (BSPED) conducted a national health professional survey in England, Wales, Scotland, and Northern Ireland looking at CGM access to funding for children and young people with recurrent hypoglycemia, without the diagnosis of diabetes. The UK Children's Hyperinsulinism Charity (UK CHC) also conducted a national patient survey. Results: Responses from BSPED were received from 55 units while the UK CHC received 69 responses from individual families, the largest response to a survey carried out by the charity. The results of the BSPED and UK CHC surveys found that funding streams for CGM were highly variable. Only 29% were able to access CGM for recurrent hypoglycemia and from these, 65% were self-funding CGM. Quality of life benefits were evident from the UK CHC survey on the utility of CGM in reducing worry, improving sleep, lessening the burden of frequently finger-pricking and reducing out-of-hours appointments as a result of hypoglycemia. Patient-reported utilization rates of blood glucose test strips per week were significantly reduced. Conclusion: BSPED and UK CHC national surveys support a call and a consideration for CGM access to be widened to patients who suffer from recurrent hypoglycemia such as those with hyperinsulinism or metabolic conditions. The prevention of recurrent hypoglycemia and improving quality of life for patients and carers remain a cornerstone management for people who suffer from frequent hypoglycemia. CGM education is critical to support its use and understand its limitations. Further research is warranted to determine the safety and efficacy of CGM in detection and reduction of hypoglycemic events, impact of hospital stay, and long-term neurological outcomes in those who suffer from recurrent hypoglceamia.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jendso/bvad021

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Parents and carers described a reduction in unplanned hospital admissions due to hypoglycaemia with continuous glucose monitoring use.

    “Parents and carers also described marked improvement in the quality of life with CGM use and a reduction in unplanned hospital admissions due to hypoglycaemia (65).”

    From Hypoglycaemia in adrenal insufficiency (2023) · cites this paper as [65]

  • A recent large survey in the UK revealed a high demand for continuous glucose monitoring in patients with recurrent hypoglycaemia without diabetes.

    “A recent large survey in the UK revealed a high demand for CGM in those patients with recurrent hypoglycaemia without diabetes and it was interesting to see how funding was obtained for some of these patients across the country.”

    From Hypoglycaemia in adrenal insufficiency (2023) · cites this paper as [65]

  • Parents and carers described marked improvement in quality of life with continuous glucose monitoring use.

    “Parents and carers also described marked improvement in the quality of life with CGM use and a reduction in unplanned hospital admissions due to hypoglycaemia (65).”

    From Hypoglycaemia in adrenal insufficiency (2023) · cites this paper as [65]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 6

  1. [1]Worth C, Dunne M, Ghosh A, Harper S, Banerjee I. Continuous glucose monitoring for hypoglycaemia in children: perspectives in 2020. Pediatr Diabetes. 2020; 21(5): 697– 706. 32315515
  2. [2]Burns CM, Rutherford MA, Boardman JP, Cowan FM. Patterns of cerebral injury and neurodevelopmental outcomes after symptomatic neonatal hypoglycemia. Pediatrics. 2008; 122(1): 65– 74. 18595988
  3. [4]Ferguson EC, Wright N, Regan F, et al Variations in access to continuous glucose monitoring and flash glucose sensors for children and young people in England and Wales: a national survey. Arch Dis Child. 2020; 105(6): 609– 610. 31527045
  4. [5]Worth C, Harper S, Salomon-Estebanez M, et al Clustering of hypoglycemia events in patients with hyperinsulinism: extension of the digital phenotype through retrospective data analysis. J Med Internet Res. 2021; 23(10): e26957. 10.2196/26957 34435596 PMC8590184 · DOI
  5. [6]Ng SM, Moore HS, Clemente M, Pintus D, Soni A. Continuous glucose monitoring in children with type 1 diabetes improves well-being, alleviates worry and fear of hypoglycaemia. Diabetes Technol Ther. 2019; 21(3): 133– 137. 30785768
  6. [7]Soni A, Wright N, Agwu JC, et al Fifteen-minute consultation: Practical use of continuous glucose monitoring. Arch Dis Child Educ Pract Ed. 2022; 107(3): 188– 193. 10.1136/archdischild-2020-321190 33963071 PMC9125373 · DOI

Cited by

Sorted by citations

Authors
Ng, S. M., Dearman, S., Fisher, M., Mushtaq, T., & Randell, T.
Affiliations
  • Southport and Ormskirk Hospital NHS Trust (GB)
  • UK Children's Hyperinsulinism Charity, Registration no 1165562 , London , UK
  • Leeds Teaching Hospitals NHS Trust (GB)
  • Nottingham University Hospitals NHS Trust (GB)
Corresponding author
Ng, Sze May
Venue
Journal of the Endocrine Society
Published
2023-01-30
Volume
7
Issue
4
Pages
bvad021-bvad021
ISSN
2472-1972 (ISSN-L)
OpenAlex
W4318479523
Cited by
6
References
0
Citations by year
2025: 2 · 2024: 2 · 2023: 2
FWCI
1.23
Type
journal article
Language
en
Open access
Locations
  • Journal of the Endocrine Society (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Edge Hill University Research Information Repository (Edge Hill University) (submittedVersion, cc-by)
Funders
Diabetes UK
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
  • Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
Keywords
continuous glucose monitoring, recurrent hypoglycemia, hyperinsulinism, children and young people, self-financing, quality of life, blood glucose test strips, pediatric endocrinology, NICE guidelines

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review