Diagnostic value of high-resolution sonography in ulnar neuropathy at the elbow
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine the diagnostic value of high-resolution sonography in ulnar neuropathy at the elbow (UNE). METHODS: Sonographic ulnar nerve diameter measurement was compared at three levels around the medial epicondyle with a criterion standard including clinical and electrophysiologic characteristics in a cohort of 123 patients presenting with clinical signs of UNE. UNE or probable UNE was diagnosed in 84 patients and a different condition in 39 patient controls. Reference values were obtained in 56 healthy volunteers. RESULTS: One hundred thirty-six affected arms were studied in 123 patients (UNE in 82, probable UNE in 9, and a different condition in 45 affected arms). Patients with UNE had a larger ulnar nerve diameter than patient controls (p < 0.0001). The sensitivity of sonography was 80%, specificity 91%, positive likelihood ratio 9, and negative likelihood ratio 0.2. The highest diagnostic yield was found in patients in whom electrodiagnostic studies showed signs of ulnar neuropathy but could not localize the lesion (17/20 cases, 86%) and in patients who had motor conduction velocity slowing across the elbow without conduction block (32/37 cases, 86%). CONCLUSIONS: High-resolution sonography is an accurate and easily applied test for the diagnosis of UNE. The authors recommend its use in addition to electrodiagnostic studies because it improves the reliability of the diagnosis of UNE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of methodological standards in diagnostic test research. Getting better but still not good
Reid, M. C. (1995) · JAMA · doi:10.1001/jama.274.8.645 · Cited by 712
Pathophysiology of Nerve Compression Syndromes: Response of Peripheral Nerves to Loading*
REMPEL, D., DAHLIN, L., & LUNDBORG, G. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199911000-00013 · Cited by 378
Pathology of experimental nerve compression.
Powell, H. C., & Myers, R. R. (1986) · PubMed · Cited by 195
ULNAR NERVE MOTOR CONDUCTION TO THE ABDUCTOR DIGITI MINIMI1
Buschbacher, R. M. (1999) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199911001-00003 · Cited by 37
Cited by
Treatment for ulnar neuropathy at the elbow
Caliandro, P., La Torre, G., Padua, R., Giannini, F., & Padua, L. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006839.pub4 · Cited by 242
The validity of upper-limb neurodynamic tests for detecting peripheral neuropathic pain.
Nee, R. J., Jull, G. A., Vicenzino, B., & Coppieters, M. W. (2012) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2012.3988 · Cited by 171
Metadata
- Authors
- Beekman, R., Schoemaker, M. C., van der Plas, J. P. L., van den Berg, L. H., Franssen, H., Wokke, J. H. J., Uitdehaag, B. M. J., & Visser, L. H.
- Venue
- Neurology
- Published
- 2004-03-09
- Volume
- 62
- Issue
- 5
- Pages
- 767-773
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2079385067
- Cited by
- 233
- References
- 4
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic value of high-resolution sonography in ulnar neuropathy at the elbow. https://app.cochat.ai/papers/10.1212/01.wnl.0000113733.62689.0d
- The paper
- Beekman, R., Schoemaker, M. C., van der Plas, J. P. L., van den Berg, L. H., Franssen, H., Wokke, J. H. J., Uitdehaag, B. M. J., & Visser, L. H. (2004). Diagnostic value of high-resolution sonography in ulnar neuropathy at the elbow. Neurology. https://doi.org/10.1212/01.wnl.0000113733.62689.0d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.