Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 205

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Evaluation of carotid stenosis using CT angiography in the initial evaluation of stroke and TIA

Josephson, S. A., Bryant, S. O., Mak, H. K., Johnston, S. C., Dillon, W. P., Smith, W. S.·2004·Neurology

Abstract

BACKGROUND: Imaging of the carotid arteries is important for the evaluation of patients with ischemic stroke or TIA. CT angiography (CTA) of the head and neck is readily available and can be part of the routine imaging of stroke patients. To evaluate the accuracy of CTA, the authors compared the degree of stenosis found using CTA with digital subtraction angiography (DSA) in consecutive patients during a 3-year period. METHODS: The authors included all patients with interpretable CTA and DSA of the cervical carotid arteries from April 2000 to November 2002 at a single academic medical center. This yielded a total of 81 vessels. Stenosis on CTA of the internal carotid artery was measured in the axial plane at the point of maximum stenosis and referenced to the distal cervical internal carotid by two blinded readers. Two blinded readers measured stenosis from the DSA using the North American Symptomatic Carotid Endarterectomy Trial method. RESULTS: Using a 70% cutoff value for stenosis, CTA and DSA were in agreement in 78 of 81 (96%; 95% CI, 90 to 99%) vessels. CTA was 100% sensitive (n = 5) and 63% specific (95% CI, 25 to 88%), and the negative predictive value of a CTA demonstrating <70% stenosis was 100% (n = 73). CONCLUSIONS: In this consecutive series of patients with CT angiography of the neck and digital subtraction angiography, the authors found that CT angiography has a high sensitivity and high negative predictive value for carotid disease. CT angiography appears to be an excellent screening test for internal carotid artery stenosis, and the authors advocate its use for the initial imaging of patients with suspected stroke or TIA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/01.wnl.0000135154.53953.2c

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 205

Metadata

Authors
Josephson, S. A., Bryant, S. O., Mak, H. K., Johnston, S. C., Dillon, W. P., & Smith, W. S.
Venue
Neurology
Published
2004-08-10
Volume
63
Issue
3
Pages
457-460
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W2029089798
Cited by
205
References
2
FWCI
9.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of carotid stenosis using CT angiography in the initial evaluation of stroke and TIA. https://app.cochat.ai/papers/10.1212/01.wnl.0000135154.53953.2c
The paper
Josephson, S. A., Bryant, S. O., Mak, H. K., Johnston, S. C., Dillon, W. P., & Smith, W. S. (2004). Evaluation of carotid stenosis using CT angiography in the initial evaluation of stroke and TIA. Neurology. https://doi.org/10.1212/01.wnl.0000135154.53953.2c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.