The DOI matches its Crossref record.
Electroencephalography: Basic Principles, Clinical Applications, and Related Fields, Fifth Edition
Abstract
Highly differentiated human proximal tubule (HPT) cells in primary culture were established from heterogeneous suspension of tubules prepared from the human renal cortex by an original two-step procedure. First, gluconeogenic-competent HPT cells were selected by using a hormonally defined serum-free medium without glucose or insulin; then, the selected HPT cells were grown in a medium containing a low concentration of glucose (1 mM) and insulin (0.5 micrograms/mL) but no antibiotics. HPT cells grown on plastic support formed confluent, cobblestone-like monolayers with numerous mitochondria and pinocytosis vacuoles, solitary cilia, junctional complexes, and a well-developed brush border consisting of densely packed microvilli. Compared with cell monolayers on plastic support, HPT cells grown on porous filter membranes showed better morphologic differentiation. HPT cell monolayers expressed the following differentiated functions of the proximal tubule in situ: a low-affinity, high-capacity Na(+)-dependent glucose transport system inhibited by phlorizin, a high-affinity Na(+)-dependent phosphate transport system, a basolateral organic cation uptake inhibited by mepiperphenidol, parathyroid hormone-sensitive cAMP synthesis, brush-border hydrolase activities, gluconeogenesis-associated enzymes, glutathione-S-transferases and N-acetyl-beta-D-glucosaminidase. The medium containing low glucose and insulin concentrations markedly limited the increase in glycolysis but did not prevent the falls in gluconeogenesis and brush-border hydrolase activity at any time of the culture period. Similar decreases of brush border enzyme activities were obtained for HPT cells grown either on plastic or on porous filter membrane. A thorough characterization study demonstrated that this simple and preparative experimental approach makes it possible to establish highly differentiated HPT cells in primary culture suitable for investigating human renal proximal tubular cell function.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because the EEG collection for the P300 speller is noninvasive, the resulting signal-to-noise ratio (SNR) is low [12].”
From A Cascade xDAWN EEGNet Structure for Unified Visual-Evoked Related Potential Detection (2024) · cites this paper as [12]
Citations
Cites
Still being checked.
Cited by
Sorted by citations
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,274
Endogenous electric fields may guide neocortical network activity
Fröhlich, F., & McCormick, D. A. (2010) · Neuron · doi:10.1016/j.neuron.2010.06.005 · Cited by 913
Removal of Artifacts from EEG Signals: A Review
Xiao, J., Bian, G., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 900
Research Review for Broad Learning System: Algorithms, Theory, and Applications
Gong, X., Zhang, T., Chen, C. L. P., & Liu, Z. (2021) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2021.3061094 · Cited by 361
Soft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
Metadata
- Authors
- Henry, J. C.
- Corresponding author
- Henry, J. Craig
- Venue
- Neurology
- Published
- 2006-12-12
- Volume
- 67
- Issue
- 11
- Pages
- 2092
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2101640127
- Cited by
- 190
- References
- 0
- Citations by year
- 2026: 18 · 2025: 19 · 2024: 18 · 2023: 25 · 2022: 49 · 2021: 24 · 2020: 12 · 2019: 5 · 2018: 3 · 2017: 1 · 2016: 3 · 2015: 2 · 2013: 2 · 2012: 1
- FWCI
- 0.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Neurology (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion Transport and Channel Regulation
- Health Sciences › Medicine › Clinical Neurology › Cerebrospinal fluid and hydrocephalus
- Keywords
- EEG, EEG signal processing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review