Effect of 4-aminopyridine on vision in multiple sclerosis patients with optic neuropathy
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: The objective of this randomized, double-blind, placebo-controlled, crossover study was to examine if patients with optic neuropathy would derive a therapeutic benefit from 4-aminopyridine (4-AP) treatment. Furthermore, the study was intended to determine if patients with certain P100 latencies or retinal nerve fiber layer (RNFL) measures would be more likely to respond to therapy. METHODS: Patients were enrolled in a randomized, placebo-controlled, double-blind, crossover study of 10 weeks duration. Patients underwent visual evoked potentials (VEP), optical coherence tomography (OCT), and visual acuity before starting 5 weeks of either placebo or 4-AP. After 5 weeks, they completed a second evaluation (VEP, OCT, and visual acuity) and were crossed over between treatment arms. Five weeks later, they had their final evaluation. All investigators were blinded to treatment arm until after data analysis. RESULTS: On average, patients had faster P100s on 4-AP when compared to placebo. A subset of patients had distinct responses to 4-AP as measured by improvements in visual acuity. Finally, eyes with an RNFL measure between 60 and 80 µm had the highest response rate. CONCLUSIONS: 4-Aminopyridine is useful for improving vision in patients with demyelinating optic neuropathy. Future clinical trials may be able to enrich a patient population for potential responders using OCT and VEP measures. Selecting patients for future trials should use RNFL measures as part of inclusion/exclusion criteria. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence supporting the use of 4-AP in certain patients with optic neuropathy to improve visual function (patients with RNFL between 60 and 80 µm).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Green, A. J., Gelfand, J. M., Cree, B. A., Bevan, C., Boscardin, W. J., Mei, F., Inman, J., Arnow, S., Devereux, M., Abounasr, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32346-2 · Cited by 593
The node of Ranvier in CNS pathology
Arancibia-Carcamo, I. L., & Attwell, D. (2014) · Acta Neuropathologica · doi:10.1007/s00401-014-1305-z · Cited by 177
Balcer, L. J., Raynowska, J., Nolan, R., Galetta, S. L., Kapoor, R., Benedict, R., Phillips, G., LaRocca, N., Hudson, L., Rudick, R., et al. (2017) · Multiple Sclerosis Journal · doi:10.1177/1352458517690822 · Cited by 168
Clinical features of MS associated with Leber hereditary optic neuropathy mtDNA mutations
Pfeffer, G., Burke, A., Yu-Wai-Man, P., Compston, D. A. S., & Chinnery, P. F. (2013) · Neurology · doi:10.1212/01.wnl.0000437308.22603.43 · Cited by 122
Metadata
- Authors
- Horton, L., Conger, A., Conger, D., Remington, G., Frohman, T., Frohman, E., & Greenberg, B.
- Venue
- Neurology
- Published
- 2013-05-14
- Volume
- 80
- Issue
- 20
- Pages
- 1862-1866
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2155680556
- Cited by
- 44
- References
- 0
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of 4-aminopyridine on vision in multiple sclerosis patients with optic neuropathy. https://app.cochat.ai/papers/10.1212/wnl.0b013e3182929fd5
- The paper
- Horton, L., Conger, A., Conger, D., Remington, G., Frohman, T., Frohman, E., & Greenberg, B. (2013). Effect of 4-aminopyridine on vision in multiple sclerosis patients with optic neuropathy. Neurology. https://doi.org/10.1212/wnl.0b013e3182929fd5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.