Quantitative assessment of parkinsonian and essential tremor: Clinical application of triaxial accelerometry
The DOI matches its Crossref record.
Abstract
Triaxial accelerometry was used to study various motion characteristics in 10 patients with Parkinson disease and 11 patients with essential tremor. The smoothness of motion factor (SPMEF) and the acceleration waveform factor (TIPAR) were frequently and consistently abnormal. When both factors were analyzed together and compared with a control population, 100% of the left arm and 88% of the right arm values were abnormal in the Parkinson disease group, and 82% of the left arm and 91% of the right arm values were abnormal in the essential tremor patients. Repeat evaluation revealed consistent intrapatient results. Therefore, this technique may provide an objective assessment of movement disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
Essential tremor and cerebellar dysfunction Clinical and kinematic analysis of intention tremor
Deuschl, G. (2000) · Brain · doi:10.1093/brain/123.8.1568 · Cited by 365
Blepharospasm and orofacial‐cervical dystonia: Clinical and pharmacological findings in 100 patients
Jankovic, J., & Ford, J. (1983) · Annals of Neurology · doi:10.1002/ana.410130406 · Cited by 318
Self-citationKinematic analysis of thalamic versus subthalamic neurostimulation in postural and intention tremor
Herzog, J., Hamel, W., Wenzelburger, R., Pötter, M., Pinsker, M. O., Bartussek, J., Morsnowski, A., Steigerwald, F., Deuschl, G., & Volkmann, J. (2007) · Brain · doi:10.1093/brain/awm077 · Cited by 230
“Clinically clearly defined as a tremor with increasing amplitude during movements towards a target (Deuschl et al., 1998), the electrophysiological assessment of intention tremor is difficult (Frost, 1978; Jankovic and Frost, 1981).”
BackgroundAssociation between essential tremor and Parkinson's disease
Geraghty, J. J., Jankovic, J., & Zetusky, W. J. (1985) · Annals of Neurology · doi:10.1002/ana.410170404 · Cited by 165
Self-citation
Metadata
- Authors
- Jankovic, J., & Frost, J. D.
- Venue
- Neurology
- Published
- 1981-10
- Volume
- 31
- Issue
- 10
- Pages
- 1235-1235
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2022530874
- Cited by
- 41
- References
- 0
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative assessment of parkinsonian and essential tremor: Clinical application of triaxial accelerometry. https://app.cochat.ai/papers/10.1212/wnl.31.10.1235
- The paper
- Jankovic, J., & Frost, J. D. (1981). Quantitative assessment of parkinsonian and essential tremor: Clinical application of triaxial accelerometry. Neurology. https://doi.org/10.1212/wnl.31.10.1235
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.