Transcranial magnetic stimulation in patients with epilepsy
The DOI matches its Crossref record.
Abstract
We studied the effects of transcranial magnetic stimulation (TMS) applied in trains of 8- to 25-Hz stimuli on electroencephalographic epileptiform activity on eight patients being evaluated for epilepsy surgery. We performed the stimulation with a round water-cooled stimulation coil held flat on the scalp and centered over different positions of the International 10-20 System. We were unable to trigger seizures or induce epileptiform discharges arising from the epileptic focus in any of the eight patients with any of the stimulation protocols. However, we induced a partial motor seizure from the contralateral hemisphere to the exclusive temporal focus in the only patient stimulated with 100% maximal intensity. Precautions have to be taken when applying rapid TMS to patients because of the risk of seizure induction. Our results do not support the view that TMS specifically activates the epileptic foci.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
“In some epilepsy patients, a seizure has occurred during rTMS, but this could not unequivocally be assigned to TMS in many cases or occurred at high TMS intensity beyond safety guidelines (Dhuna et al., 1991).”
BackgroundWassermann, E. M. (1998) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/s0168-5597(97)00096-8 · Cited by 2,293
Rossi, S., Antal, A., Bestmann, S., Bikson, M., Brewer, C., Brockmöller, J., Carpenter, L. L., Cincotta, M., Chen, R., Daskalakis, J. D., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.10.003 · Cited by 1,573
“Regarding the two cases of seizures that occurred after temporal or parietal stimulation (Dhuna et al., 1991; Nowak et al., 2006),”
Fregni, F., & Pascual-Leone, A. (2007) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0530 · Cited by 823
Self-citationHuman motor evoked responses to paired transcranial magnetic stimuli
Valls-Solé, J., Pascual-Leone, A., Wassermann, E. M., & Hallett, M. (1992) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(92)90048-g · Cited by 687
Self-citation
Metadata
- Authors
- Dhuna, A., Gates, J., & Pascual-Leone, A.
- Venue
- Neurology
- Published
- 1991-07
- Volume
- 41
- Issue
- 7
- Pages
- 1067-1067
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2121047670
- Cited by
- 130
- References
- 0
- FWCI
- 4.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transcranial magnetic stimulation in patients with epilepsy. https://app.cochat.ai/papers/10.1212/wnl.41.7.1067
- The paper
- Dhuna, A., Gates, J., & Pascual-Leone, A. (1991). Transcranial magnetic stimulation in patients with epilepsy. Neurology. https://doi.org/10.1212/wnl.41.7.1067
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.