CoChat
Cited by 134

The DOI matches its Crossref record.

Longitudinal MRI in multiple sclerosis: Correlation between disability and lesion burden

Khoury, S. J., Guttmann, C.R.G., Orav, E. J., Hohol, M. J., Ahn, S. S., Hsu, L., Kikinis, R., Mackin, G. A., Jolesz, F. A., Weiner, H. L. · 1994 · Neurology

Abstract

811 Objectives: In patients with non-palpable breast cancer, surgical tumor localization has been achieved by wire localization (WL). Wire localization has been replaced by I-125 radioactive seed localization (RSL). The objective of this study is to compare mean surgical times when using wire localization versus using I-125 seed localization. Methods: Patients from NorthShore University HealthSystem who had RSL or WL before having a lumpectomy with sentinel node biopsy (SNB) or sentinel lymph node biopsy (SLNB) due to non-palpable breast tumors were analyzed. Sample size was selected based on having a lumpectomy from one specific surgeon. Surgical times for all WL were obtained between the year of 2014-2015, n=31, while surgical times for all RSL were obtained between the year of 2015-2016, n=31. The surgical times collected were recorded from cut to close. An independent-sample t-test was used to compare the means of surgical times when using WL and when using RSL. Results: An independent-sample t-test showed that there was a statistically significant difference between surgical times when using WL (M=56, SD=17) and surgical times when using RSL (M=47.6, SD=14.6), p = 0.039. Mean procedure time when using RSL was 8.52 minutes shorter than mean procedure time when using WL. Conclusion: RSL is a good alternative for the WL. One benefit is a significantly lower mean surgical time when using RSL compared to WL. Additional research with a larger sample size could be conducted to further confirm the results of this study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/wnl.44.11.2120

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 134

Metadata

Authors
Khoury, S. J., Guttmann, C. R. G., Orav, E. J., Hohol, M. J., Ahn, S. S., Hsu, L., Kikinis, R., Mackin, G. A., Jolesz, F. A., & Weiner, H. L.
Venue
Neurology
Published
1994-11
Volume
44
Issue
11
Pages
2120-2120
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W2053465447
Cited by
134
References
0
FWCI
8.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Longitudinal MRI in multiple sclerosis: Correlation between disability and lesion burden. https://app.cochat.ai/papers/10.1212/wnl.44.11.2120
The paper
Khoury, S. J., Guttmann, C. R. G., Orav, E. J., Hohol, M. J., Ahn, S. S., Hsu, L., Kikinis, R., Mackin, G. A., Jolesz, F. A., & Weiner, H. L. (1994). Longitudinal MRI in multiple sclerosis: Correlation between disability and lesion burden. Neurology. https://doi.org/10.1212/wnl.44.11.2120

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.