The DOI matches its Crossref record.
Subtraction ictal SPECT co‐registered to MRI improves clinical usefulness of SPECT in localizing the surgical seizure focus
Abstract
Traditional side-by-side visual interpretation of ictal and interictal single-photon emission computed tomography (SPECT) scans can be difficult in identifying the surgical focus, particularly in patients with extratemporal or otherwise unlocalized intractable epilepsy. Computer-aided subtraction ictal SPECT co-registered to MRI (SISCOM) may improve the clinical usefulness of SPECT in localizing the surgical seizure focus. We studied 51 consecutive intractable partial epilepsy patients who had interictal and ictal scans. The SPECT studies were blindly reviewed and classified as either localizing to 1 of 16 sites in the brain or as nonlocalizing. SISCOM images were localizing in 45 of 51 (88.2%) compared with 20 of 51 (39.2%) for traditional side-by-side inspection of ictal and interictal SPECT images (p < 0.0001). Inter-rater agreement for two independent reviewers was better for SISCOM (84.3% versus 41.2%, kappa = 0.83 versus 0.26; p < 0.0001). Concordance of seizure localization with the more established tests was also higher for SISCOM. Late injection of the radiotracer (> 45 seconds), but not secondary generalization of the seizure, was associated with a falsely localizing or nonlocalizing SISCOM. Epilepsy surgery patients whose SISCOM localization was concordant with a falsely localizing or nonlocalizing SISCOM. Epilepsy surgery patients whose SISCOM localization was concordant with the surgical site were more likely to have excellent outcome than patients with nonconcordant or nonlocalizing findings (62.5% [10/16] versus 20% [2/10]; p < 0.05). On the other hand, seizure localization by the traditional method of SPECT inspection had no significant association with postsurgical outcome. We conclude that SISCOM improves the sensitivity and the specificity of SPECT in localizing the seizure focus for epilepsy surgery. Concordance between SISCOM localization and site of surgery is predictive of postsurgical improvement in seizure outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Positive and Negative Network Correlations in Temporal Lobe Epilepsy
Blumenfeld, H., McNally, K. A., Vanderhill, S. D., Paige, A. L., Chung, R., Davis, K., Norden, A. D., Stokking, R., Studholme, C., Novotny, E. J., et al. (2004) · Cerebral Cortex · doi:10.1093/cercor/bhh048 · Cited by 332
PET and SPECT in epilepsy: a critical review.
la Fougère, C., Rominger, A., Förster, S., Geisler, J., & Bartenstein, P. (2009) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2009.02.025 · Cited by 224
Cerebral perfusion changes during cataplexy in narcolepsy patients
Hong, S. B., Tae, W. S., & Joo, E. Y. (2006) · Neurology · doi:10.1212/01.wnl.0000218205.72668.ab · Cited by 79
Metadata
- Authors
- O'Brien, T. J., So, E. L., Mullan, B. P., Hauser, M. F., Brinkmann, B. H., Bohnen, N. I., Hanson, D., Cascino, G. D., Jack, C. R., & Sharbrough, F. W.
- Venue
- Neurology
- Published
- 1998-02
- Volume
- 50
- Issue
- 2
- Pages
- 445-454
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2043158507
- Cited by
- 530
- References
- 0
- FWCI
- 15.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subtraction ictal SPECT co‐registered to MRI improves clinical usefulness of SPECT in localizing the surgical seizure focus. https://app.cochat.ai/papers/10.1212/wnl.50.2.445
- The paper
- O'Brien, T. J., So, E. L., Mullan, B. P., Hauser, M. F., Brinkmann, B. H., Bohnen, N. I., Hanson, D., Cascino, G. D., Jack, C. R., & Sharbrough, F. W. (1998). Subtraction ictal SPECT co‐registered to MRI improves clinical usefulness of SPECT in localizing the surgical seizure focus. Neurology. https://doi.org/10.1212/wnl.50.2.445
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.