Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Evaluation of early reperfusion and IV tPA therapy using diffusion- and perfusion-weighted MRI

Marks, M.P., Tong, D.C., Beaulieu, C., Albers, G.W., de Crespigny, A., Moseley, M.E.·1999·Neurology

Abstract

OBJECTIVE: To characterize the effects of recombinant tissue plasminogen activator (rt-PA) therapy and early reperfusion on diffusion-weighted (DWI) and perfusion-weighted imaging (PWI) changes observed following acute ischemic injury. METHODS: Twelve patients were evaluated prospectively using echo planar DWI and bolus tracking PWI. Six patients received i.v. rt-PA 0.9 mg/kg and were compared with six patients who did not. Patients receiving rt-PA were initially imaged (T1) 3 to 5 hours postictus (mean, 4 hours 20 minutes) whereas those not treated with tissue plasminogen activator (tPA) were imaged 4 to 7 hours postictus (mean, 5 hours, 25 minutes). Follow-up imaging was performed 3 to 6 hours (T2), 24 to 36 hours (T3), 5 to 7 days (T4), and 30 days (T5) after the first scan in all patients. Lesion volumes were measured on both DWI and time-to-peak maps constructed from PW images. RESULTS: PWI was performed successfully at T1 and T3 in 11 of 12 patients. In the group that received i.v. tPA, initial PWI volumes were less than DWI volumes in five of six patients (83%), whereas only one of five patients (20%) not receiving tPA had PWI < DWI volume (p = 0.08). PWI normalized by 24 to 36 hours (T3) in 6 of 11 patients (early reperfusers), with 5 of 6 of these early reperfusers having received tPA. The aggregate apparent diffusion coefficient (ADC) values for the early reperfusers were consistently higher at T2 (p = 0.04), T3 (p = 0.002), and T4 (p = 0.0005). Five of six patients with early reperfusion demonstrated regions of elevated ADC within the ischemic zone (mean ipsilateral ADC/contralateral ADC, 1.46 +/- 0.19) by 24 to 36 hours, whereas none of the nonearly reperfusers showed these regions of elevated ADC (p = 0.015). CONCLUSION: Early reperfusion is seen more frequently with i.v. tPA therapy. In addition, the study showed that ADC may undergo early increases that are tied closely to reperfusion, and marked ADC heterogeneity may exist within the same lesion. Early reperfusion is seen more frequently with i.v. tPA therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/wnl.52.9.1792

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 196

Metadata

Authors
Marks, M. P., Tong, D. C., Beaulieu, C., Albers, G. W., de Crespigny, A., & Moseley, M. E.
Venue
Neurology
Published
1999-06
Volume
52
Issue
9
Pages
1792-1792
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W1988631838
Cited by
196
References
1
FWCI
20.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of early reperfusion and IV tPA therapy using diffusion- and perfusion-weighted MRI. https://app.cochat.ai/papers/10.1212/wnl.52.9.1792
The paper
Marks, M. P., Tong, D. C., Beaulieu, C., Albers, G. W., de Crespigny, A., & Moseley, M. E. (1999). Evaluation of early reperfusion and IV tPA therapy using diffusion- and perfusion-weighted MRI. Neurology. https://doi.org/10.1212/wnl.52.9.1792

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.