The DOI matches its Crossref record.
Continuous Monitoring of Mixed Venous Oxygen Saturation in Critically Ill Patients
Abstract
A new pulmonary artery balloon flow-directed catheter combines a fiberoptic photometric system for continuous display of mixed venous blood oxygen saturation (SvO2) with the capacity for hemodynamic measurements including thermodilution cardiac output estimation. This oximetry system was studied to determine its accuracy, reliability, and usefulness in the surgical intensive care unit (ICU). Twenty-two catheters were tested, but only 17 were successfully placed in 16 patients. There were technical problems associated with 10 catheters and on six occasions these necessitated the use of another catheter. The catheter values for SvO2 were closely related (r = 0.9516) to those obtained from a laboratory Co-oximeter. Continuous monitoring of SvO2 is accurate and valuable as a warning system for deterioration in cardiopulmonary function and as an indicator of the effects of various therapeutic maneuvers in critically ill patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Trial of Goal-Oriented Hemodynamic Therapy in Critically Ill Patients
Gattinoni, L., Brazzi, L., Pelosi, P., Latini, R., Tognoni, G., Pesenti, A., & Fumagalli, R. (1995) · New England Journal of Medicine · doi:10.1056/nejm199510193331601 · Cited by 1,510
Reinhart, K., Rudolph, T., Bredle, D. L., Hannemann, L., & Cain, S. M. (1989) · Chest · doi:10.1378/chest.95.6.1216 · Cited by 515
Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill
Reinhart, K., Kuhn, H.-J., Hartog, C., & Bredle, D. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2337-y · Cited by 437
Ferguson, D. W., Berg, W. J., Sanders, J. S., Roach, P. J., Kempf, J. S., & Kienzle, M. G. (1989) · Circulation · doi:10.1161/01.cir.80.1.65 · Cited by 382
DeWitt, D. S., & Prough, D. S. (2003) · Journal of Neurotrauma · doi:10.1089/089771503322385755 · Cited by 195
Metadata
- Authors
- Baele, P. L., McMichan, J. C., Marsh, H. M., Sill, J. C., & Southorn, P. A.
- Venue
- Anesthesia & Analgesia
- Published
- 1982-06
- Volume
- 61
- Issue
- 6
- Pages
- 513???517
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2092819724
- Cited by
- 171
- References
- 0
- FWCI
- 10.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Monitoring of Mixed Venous Oxygen Saturation in Critically Ill Patients. https://app.cochat.ai/papers/10.1213/00000539-198206000-00007
- The paper
- Baele, P. L., McMichan, J. C., Marsh, H. M., Sill, J. C., & Southorn, P. A. (1982). Continuous Monitoring of Mixed Venous Oxygen Saturation in Critically Ill Patients. Anesthesia & Analgesia. https://doi.org/10.1213/00000539-198206000-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.