CoChat

Estimation of Functional Residual Capacity at the Bedside Using Standard Monitoring Equipment: A Modified Nitrogen Washout/Washin Technique Requiring a Small Change of the Inspired Oxygen Fraction

Oleg??rd, Cecilia, S??ndergaard, S??ren, Houltz, Erik, Lundin, Stefan, Stenqvist, Ola · 2005 · Anesthesia & Analgesia
Cited by 184

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

In Brief We developed a modified nitrogen washin/washout technique based on standard monitors using inspiratory and end-tidal gas concentration values for functional residual capacity (FRC) measurements in patients with acute respiratory failure (ARF). For validation we used an oxygen-consuming lung model ventilated with an inspiratory oxygen fraction (Fio2) between 0.3 and 1.0. The respiratory quotient of the lung model was varied between 0.7 and 1.0. Measurements were performed changing Fio2 with fractions of 0.1, 0.2, and 0.3. In 28 patients with ARF, duplicate measurements were performed. In the lung model, an Fio2 change of 0.1 resulted in a value of 103 ± 5% of the reference FRC value of the lung model, and the precision was equally good up to an Fio2 of 1.0 with a value of 103 ± 7%. In the patients, duplicate measurements showed a bias of −5 mL with a 95% confidence interval [−38; 29 mL ]. A comparison of a change in Fio2 of 0.1 with 0.3 showed a bias of −9 mL and limits of agreement of [−365; 347 mL]. This study shows good precision of FRC measurements with standard monitors using a change in Fio2 of only 0.1. Measurements can be performed with equal precision up to an Fio2 of 1.0. IMPLICATIONS: Presently there is no clinical method for measuring the functional residual capacity (FRC) in mechanically ventilated patients with acute respiratory failure. We have developed a nitrogen washin/washout method for FRC measurements using standard monitors requiring only a 0.1 change in inspiratory oxygen fraction (Fio2). The method can be used up to an Fio2 of 1.0.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/01.ane.0000165823.90368.55

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 184

Metadata

Authors
Oleg??rd, C., S??ndergaard, S., Houltz, E., Lundin, S., & Stenqvist, O.
Venue
Anesthesia & Analgesia
Published
2005-07
Volume
101
Issue
1
Pages
206-212
ISSN
0003-2999 (ISSN-L)
OpenAlex
W1994406765
Cited by
184
References
2
FWCI
5.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.