CoChat

Rocuronium Versus Succinylcholine for Rapid Sequence Induction of Anesthesia and Endotracheal Intubation: A Prospective, Randomized Trial in Emergent Cases

Sluga, Mathias, Ummenhofer, Wolfgang, Studer, Wolfgang, Siegemund, Martin, Marsch, Stephan C. · 2005 · Anesthesia & Analgesia
Cited by 110

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In Brief When anesthesia is induced with propofol in elective cases, endotracheal intubation conditions are not different between succinylcholine and rocuronium approximately 60 s after the injection of the neuromuscular relaxant. In the present study, we investigated whether, in emergent cases, endotracheal intubation conditions obtained at the actual moment of intubation under succinylcholine differ from those obtained 60 s after the injection of rocuronium. One-hundred-eighty adult patients requiring rapid sequence induction of anesthesia for emergent surgery received propofol (1.5 mg/kg) and either rocuronium (0.6 mg/kg; endotracheal intubation 60 s after injection) or succinylcholine (1 mg/kg; endotracheal intubation as soon as possible). The time from beginning of the induction until completion of the intubation was shorter after the administration of succinylcholine than after rocuronium (median time 95 s versus 130 s; P < 0.0001). Endotracheal intubation conditions, rated with a 9-point scale, were better after succinylcholine administration than after rocuronium (8.6 ± 1.1 versus 8.0 ± 1.5; P < 0.001). There was no significant difference in patients with poor intubation conditions (7 versus 12) or in patients with failed first intubation attempt (4 versus 5) between the groups. We conclude that during rapid sequence induction of anesthesia in emergent cases, succinylcholine allows for a more rapid endotracheal intubation sequence and creates superior intubation conditions compared with rocuronium. IMPLICATIONS: During rapid sequence induction of anesthesia in emergent cases, succinylcholine allowed for a more rapid endotracheal intubation sequence and created superior intubation conditions compared with rocuronium. However, there was no difference in the incidence of poor intubation conditions, failed intubation attempts, and desaturations between succinylcholine and rocuronium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/01.ane.0000180196.58567.fe

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 110

Metadata

Authors
Sluga, M., Ummenhofer, W., Studer, W., Siegemund, M., & Marsch, S. C.
Venue
Anesthesia & Analgesia
Published
2005-11
Volume
101
Issue
5
Pages
1356-1361
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2049745175
Cited by
110
References
1
FWCI
8.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.