A Single Adrenocorticotropic Hormone Stimulation Test Does Not Reveal Adrenal Insufficiency in Septic Shock
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In Brief The diagnosis of adrenocortical insufficiency in critically ill patients is complex. The adrenocorticotropic hormone (ACTH) stimulation test is a widely accepted method for assessing the adequacy of adrenal function in intensive care units, but it is possible that there may be wide variations in responses to the test over a short period of time. In this prospective study, we investigated the reproducibility of the ACTH stimulation test in 20 patients with sepsis, in 20 patients with septic shock, and in 20 critically ill patients without sepsis. Two consecutive ACTH stimulation tests were performed within 24 h after intensive care unit admission or at the onset of sepsis. In patients without sepsis there was good correlation between ACTH responses on days 1 and 2 (Pearson's correlation coefficient, 0.689; P = 0.001). In contrast, in patients with septic shock no correlation was observed between the two ACTH responses (Pearson's correlation coefficient, 0.401; P = 0.080). We conclude that the results of the ACTH stimulation tests are poorly reproducible in septic shock and a single ACTH stimulation test may not be the best method to diagnose adrenal insufficiency in these patients. IMPLICATIONS: In this prospective study two consecutive adrenocorticotropic hormone (ACTH) stimulation tests were performed in 60 critically ill patients. In a subgroup of septic shock patients the test results were poorly reproducible. This suggests that the ACTH stimulation test is not a sensitive method to diagnose adrenal insufficiency in septic shock patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Annane, D. (2000) · JAMA · doi:10.1001/jama.283.8.1038 · Cited by 1,000 · cited 5×
“Most investigators have introduced their own criteria for the diagnosis of adrenocortical insufficiency (5,7,8), and many of these criteria are broadly similar to the values used in the overall hospital population.”
BackgroundMethodInfluential
Cited by
Marik, P. E., Pastores, S. M., Annane, D., Meduri, G. U., Sprung, C. L., Arlt, W., Keh, D., Briegel, J., Beishuizen, A., Dimopoulou, I., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31817603ba · Cited by 912
“In addition, the ACTH stimulation test may be poorly reproducible, especially in patients with septic shock (97, 98).”
BackgroundArafah, B. M. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-0674 · Cited by 332
Adrenal insufficiency in critical illness
Cooper, M. S., & Stewart, P. M. (2007) · Journal of Intensive Care Medicine · doi:10.1177/0885066607307832 · Cited by 97
“A further problem with this test is that it appears to have poor reproducibility in septic shock when repeated in the same patients [66,88].”
BackgroundVassiliadi, D. A., Dimopoulou, I., Tzanela, M., Douka, E., Livaditi, O., Orfanos, S. E., Kotanidou, A., & Tsagarakis, S. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-2619 · Cited by 32
Metadata
- Authors
- Loisa, P., Uusaro, A., & Ruokonen, E.
- Venue
- Anesthesia & Analgesia
- Published
- 2005-12
- Volume
- 101
- Issue
- 6
- Pages
- 1792-1798
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2076107133
- Cited by
- 65
- References
- 1
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Single Adrenocorticotropic Hormone Stimulation Test Does Not Reveal Adrenal Insufficiency in Septic Shock. https://app.cochat.ai/papers/10.1213/01.ane.0000184042.91452.48
- The paper
- Loisa, P., Uusaro, A., & Ruokonen, E. (2005). A Single Adrenocorticotropic Hormone Stimulation Test Does Not Reveal Adrenal Insufficiency in Septic Shock. Anesthesia & Analgesia. https://doi.org/10.1213/01.ane.0000184042.91452.48
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.