Continuous Oximetry/Capnometry Monitoring Reveals Frequent Desaturation and Bradypnea During Patient-Controlled Analgesia

Overdyk, Frank J., Carter, Rickey, Maddox, Ray R., Callura, Jarred, Herrin, Amy E., Henriquez, Craig·2007·Anesthesia & Analgesia

Abstract

In Brief BACKGROUND: The most serious complication of patient-controlled analgesia (PCA) is respiratory depression (RD). The incidence of RD in the literature is derived from intermittent sampling of pulse oximetry (Spo2) and respiratory rate and defined as a deviation below an arbitrary threshold. METHODS: We monitored postsurgical patients in a hospital ward receiving morphine or meperidine PCA with continuous oximetry and capnography. Nurses responding to audible monitor bedside alarms documented respiratory status and interventions. RESULTS: A total of 178 patients were included in the analysis, 12% and 41% of whom had episodes of desaturation (Spo2 <90%) and bradypnea (respiratory rate <10) lasting 3 min or more. One patient required “rescue” with positive pressure ventilation, and none required naloxone. Patients over 65 years of age and the morbidly obese were at greater risk for desaturation. Patients over 65 years of age were also more likely to have bradypnea, whereas the morbidly obese and patients receiving continuous infusions were less likely to have bradypnea. CONCLUSIONS: Our incidence of RD by bradypnea is significantly higher than the 1%–2% incidence in the literature, using the same threshold criteria but more stringent duration criteria, while our incidence of RD based on desaturation is consistent with previous estimates. We conclude that continuous respiratory monitoring is optimal for the safe administration of PCA, because any RD event can progress to respiratory arrest if undetected. Better alarm algorithms must be implemented to reduce the frequent alarms triggered by threshold criteria for RD. IMPLICATIONS: Continuous patient monitoring by pulse oximetry and capnometry during narcotic administration via patient-controlled analgesia suggests that the incidence of desaturation and bradypnea exceeds that documented by intermittent monitoring. Continuous monitoring may be important to prevent adverse events related to narcotic administration, but additional research is needed to reduce the rate of false positive alarms and to understand the true incidence of this problem.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/01.ane.0000269489.26048.63

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 191

Metadata

Authors
Overdyk, F. J., Carter, R., Maddox, R. R., Callura, J., Herrin, A. E., & Henriquez, C.
Venue
Anesthesia & Analgesia
Published
2007-08
Volume
105
Issue
2
Pages
412-418
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2068095005
Cited by
191
References
0
FWCI
8.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous Oximetry/Capnometry Monitoring Reveals Frequent Desaturation and Bradypnea During Patient-Controlled Analgesia. https://app.cochat.ai/papers/10.1213/01.ane.0000269489.26048.63
The paper
Overdyk, F. J., Carter, R., Maddox, R. R., Callura, J., Herrin, A. E., & Henriquez, C. (2007). Continuous Oximetry/Capnometry Monitoring Reveals Frequent Desaturation and Bradypnea During Patient-Controlled Analgesia. Anesthesia & Analgesia. https://doi.org/10.1213/01.ane.0000269489.26048.63

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.