The Analgesic Efficacy of Ultrasound-Guided Transversus Abdominis Plane Block in Adult Patients: A Meta-Analysis
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Previous meta-analyses of the transversus abdominis plane (TAP) block have examined a maximum of 12 articles, including fewer than 650 participants, and have not examined the effect of ultrasound-guided techniques specifically. Recently, many trials that use ultrasound approaches to TAP block have been published, which report conflicting analgesic results. This meta-analysis aims to evaluate the analgesic efficacy of ultrasound-guided TAP blocks exclusively for all types of abdominal surgeries in adult patients. METHODS: This meta-analysis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement guidelines. The primary outcome was cumulative IV morphine consumption at 6 hours postoperatively, analyzed according to the type of surgery, the type of surgical anesthesia, the timing of injection, the block approach adopted, and the presence of postoperative multimodal analgesia. Secondary outcomes included IV morphine consumption at 24 hours postoperatively; pain scores at rest and on movement at 6 and 24 hours postoperatively; and postoperative nausea and vomiting, pruritus, and rates of complications. RESULTS: Thirty-one controlled trials including 1611 adult participants were identified. Independent of the type of surgery (abdominal laparotomy, abdominal laparoscopy, and cesarean delivery) but not independent of the type of surgical anesthesia (general anesthesia, spinal anesthesia with or without intrathecal long-acting opioid), ultrasound-guided TAP block reduced IV morphine consumption at 6 hours postoperatively by a mean difference of 6 mg (95% confidence interval [CI], -7 to -4 mg; I2 = 94%; P < 0.00001). The magnitude of the reduction in morphine consumption at 6 hours postoperatively was not influenced by the timing of injection (I2 = 0%; P = 0.72), the block approach adopted (I2 = 0%; P = 0.72), or the presence of postoperative multimodal analgesia (I2 = 73%; P = 0.05). This difference persisted at 24 hours postoperatively (mean difference, -11 mg; 95% CI, -14 to -8 mg; I2 = 99%; P < 0.00001). Pain scores at rest and on movement were reduced at 6 hours postoperatively (mean difference at rest, -10; 95% CI, -15 to -5; I2 = 92%; P = 0.0002; mean difference on movement, -9; 95% CI, -14 to -5; I2 = 58%; P < 0.00001). There were neither differences in the incidence of postoperative nausea and vomiting (I2 = 1%; P = 0.59) nor in the pruritus (I2 = 12%; P = 0.58) Two minor complications (1 bruise and 1 anaphylactoid reaction) were reported in 1028 patients. CONCLUSIONS: Ultrasound-guided TAP block provides marginal postoperative analgesic efficacy after abdominal laparotomy or laparoscopy and cesarean delivery. However, it does not provide additional analgesic effect in patients who also received spinal anesthesia containing a long-acting opioid. The minimal analgesic efficacy is independent of the timing of injection, the approach adopted, or the presence of postoperative multimodal analgesia. Because of heterogeneity of the results, these findings should be interpreted with caution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
Duval, S., & Tweedie, R. (2000) · Biometrics · doi:10.1111/j.0006-341x.2000.00455.x · Cited by 14,099
CONSORT 2010 Statement: updated guidelines for reporting parallel group randomised trials
the CONSORT Group, Schulz, K. F., Altman, D. G., & Moher, D. (2010) · BMC Medicine · doi:10.1186/1741-7015-8-18 · Cited by 13,371
GRADE guidelines: 3. Rating the quality of evidence
Balshem, H., Helfand, M., Schünemann, H. J., Oxman, A. D., Kunz, R., Brozek, J., Vist, G. E., Falck-Ytter, Y., Meerpohl, J., & Norris, S. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.07.015 · Cited by 8,285
PETERSEN, P. L., MATHIESEN, O., TORUP, H., & DAHL, J. B. (2010) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2010.02215.x · Cited by 296
Transversus Abdominis Plane Block: A Systematic Review
Abdallah, F. W., Chan, V. W., & Brull, R. (2012) · Regional Anesthesia and Pain Medicine · doi:10.1097/aap.0b013e3182429531 · Cited by 283
Johns, N., O’Neill, S., Ventham, N. T., Barron, F., Brady, R. R., & Daniel, T. (2012) · Colorectal Disease · doi:10.1111/j.1463-1318.2012.03104.x · Cited by 272
Abdallah, F. W., Laffey, J. G., Halpern, S. H., & Brull, R. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet214 · Cited by 250
Abdallah, F. W., Halpern, S. H., & Margarido, C. B. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes279 · Cited by 236
Mishriky, B. M., George, R. B., & Habib, A. S. (2012) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-012-9729-1 · Cited by 230
De Oliveira, G. S., Castro-Alves, L. J., Nader, A., Kendall, M. C., & McCarthy, R. J. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000066 · Cited by 209
A meta-analysis on the clinical effectiveness of transversus abdominis plane block
Siddiqui, M. R. S., Sajid, M. S., Uncles, D. R., Cheek, L., & Baig, M. K. (2011) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2010.05.008 · Cited by 198
Costello, J. F., Moore, A. R., Wieczorek, P. M., Macarthur, A. J., Balki, M., & Carvalho, J. C. A. (2009) · Regional Anesthesia & Pain Medicine · doi:10.1097/aap.0b013e3181b4c922 · Cited by 195
Barreveld, A., Witte, J., Chahal, H., Durieux, M. E., & Strichartz, G. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318277a270 · Cited by 172
McMorrow, R. C. N., Ni Mhuircheartaigh, R. J., Ahmed, K. A., Aslani, A., Ng, S.-C., Conrick-Martin, I., Dowling, J. J., Gaffney, A., Loughrey, J. P. R., & McCaul, C. L. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer061 · Cited by 169
Petersen, P. L., Stjernholm, P., Kristiansen, V. B., Torup, H., Hansen, E. G., Mitchell, A. U., Moeller, A., Rosenberg, J., Dahl, J. B., & Mathiesen, O. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318261f16e · Cited by 154
Bharti, N., Parag, K., Bala, I., & Gupta, V. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182159bf8 · Cited by 153
Wu, Y., Liu, F., Tang, H., Wang, Q., Chen, L., Wu, H. B. K., Zhang, X., Miao, J., Zhu, M., Hu, C., et al. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318297fcee · Cited by 127
Griffiths, J. D., Middle, J. V., Barron, F. A., Grant, S., Popham, P., & Royse, C. F. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181e53517 · Cited by 119
Eslamian, L., Jalili, Z., Jamal, A. S., et al. (2012) · Journal of Anesthesia · doi:10.1007/s00540-012-1336-3 · Cited by 104
Ultrasound‐Guided Transversus Abdominis Plane (TAP) Block
Romano, M. (2024) · doi:10.1002/9781119514183.ch19 · Cited by 95
Bollag, L. A., Richebé, P., Siaulys, M. M., Ortner, C. M., Gofeld, M., & Landau, R. (2012) · Regional Anesthesia & Pain Medicine · doi:10.1097/aap.0b013e318259ce35 · Cited by 94
Analgesic effectiveness of transversus abdominis plane blocks after hysterectomy: a meta-analysis
Champaneria, R., Shah, L., Geoghegan, J., Gupta, J. K., & DANIELS, J. P. (2012) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2012.09.012 · Cited by 78
SKJELSAGER, A., Ruhnau, B., Kistorp, T., Kridina, I., Hvarness, H., Mathiesen, O., & Dahl, J. B. (2013) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12080 · Cited by 59
Gasanova, I., Grant, E. N., Way, M., Rosero, E. B., & Joshi, G. P. (2013) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-012-2698-3 · Cited by 43
Kim, M. G., Kim, S. I., Ok, S. Y., Kim, S. H., Lee, S. M., Park, S.-Y., Lee, S. M., & Jung, B. I. (2012) · Korean Journal of Anesthesiology · doi:10.4097/kjae.2012.63.3.227 · Cited by 22
Cited by
Wick, E. C., Grant, M. C., & Wu, C. L. (2017) · JAMA Surgery · doi:10.1001/jamasurg.2017.0898 · Cited by 1,009
Essentials of Our Current Understanding: Abdominal Wall Blocks
Chin, K. J., McDonnell, J. G., Carvalho, B., Sharkey, A., Pawa, A., & Gadsden, J. (2017) · Regional Anesthesia and Pain Medicine · doi:10.1097/aap.0000000000000545 · Cited by 416
Frauenknecht, J., Kirkham, K. R., Jacot‐Guillarmod, A., & Albrecht, E. (2019) · Anaesthesia · doi:10.1111/anae.14582 · Cited by 350
Self-citationKumar, K., Kirksey, M. A., Duong, S., & Wu, C. L. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002497 · Cited by 308
ACOG Practice Bulletin No. 209: Obstetric Analgesia and Anesthesia
(2019) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000003132 · Cited by 231
Metadata
- Authors
- Baeriswyl, M., Kirkham, K. R., Kern, C., & Albrecht, E.
- Venue
- Anesthesia & Analgesia
- Published
- 2015-12
- Volume
- 121
- Issue
- 6
- Pages
- 1640-1654
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1834717316
- Cited by
- 282
- References
- 26
- FWCI
- 18.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.