The DOI matches its Crossref record.
Target-Controlled Infusion: A Mature Technology
Abstract
Target-controlled infusions (TCIs) have been used in research and clinical practice for >2 decades. Nonapproved TCI software systems have been used during the conduct of almost 600 peer-reviewed published studies involving large numbers of patients. The first-generation pumps were first approved in 1996, and since then an estimated 25,000 units have been sold and used. Second-generation pumps were first approved in 2003. During 2004 to 2013, >36,000 units were sold. Currently, TCI systems are approved or available in at least 96 countries. TCI systems are used to administer propofol and opioids for IV sedation and general anesthesia for millions of patients every year. In countries where TCI systems are approved, nonapproved software is still commonly used in studies of the pharmacology of hypnotics and opioids, because research software offers greater flexibility than approved TCI systems. Research software is also readily integrated into data management modules. Although TCI is a part of established practice around the world, TCI devices have not received regulatory approval in the United States. In the United States, TCI administration of propofol and opioids for sedation and anesthesia is only possible using research software in IRB-approved research studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pharmacokinetic–pharmacodynamic model for propofol for broad application in anaesthesia and sedation
Eleveld, D. J., Colin, P., Absalom, A. R., & Struys, M. M. R. F. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.01.018 · Cited by 302
Self-citationRemimazolam: pharmacological characteristics and clinical applications in anesthesiology
Kim, K. M. (2022) · Anesthesia and Pain Medicine · doi:10.17085/apm.21115 · Cited by 257
Induction and maintenance of procedural sedation in adults: focus on remimazolam injection
Chen, W., Chen, S., & Huang, Y. (2021) · Expert Review of Clinical Pharmacology · doi:10.1080/17512433.2021.1901575 · Cited by 25
Metadata
- Authors
- Absalom, A. R., Glen, J. (. B., Zwart, G. J. C., Schnider, T. W., & Struys, M. M. R. F.
- Venue
- Anesthesia & Analgesia
- Published
- 2016-01
- Volume
- 122
- Issue
- 1
- Pages
- 70-78
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2408763116
- Cited by
- 189
- References
- 0
- FWCI
- 15.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Target-Controlled Infusion: A Mature Technology. https://app.cochat.ai/papers/10.1213/ane.0000000000001009
- The paper
- Absalom, A. R., Glen, J. (. B., Zwart, G. J. C., Schnider, T. W., & Struys, M. M. R. F. (2016). Target-Controlled Infusion: A Mature Technology. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000001009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.