The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Correlation Between Bispectral Index and Observational Sedation Scale in Volunteers Sedated with Dexmedetomidine and Propofol
Abstract
BACKGROUND: Bispectral index (BIS) is a widely used quantitative parameter for evaluating anesthesia and sedation levels. Dexmedetomidine is a novel sedative, providing sedation while patients remain cooperative and can be easily aroused; as a consequence, BIS used with dexmedetomidine may poorly characterize sedation. Thus, we tested the hypothesis that BIS values are lower with dexmedetomidine than with propofol at comparable Observer's Assessment of Alertness and Sedation (OAA/S) scores. METHODS: This was a randomized, 2-day, crossover study. On the first study day, healthy volunteers were randomly allocated to either propofol or dexmedetomidine sedation. Drugs were administered using computer-controlled infusions targeting an effect-site concentration of 1, 2, and 4 microg/mL for propofol or a plasma concentration of 0.6, 1.2, and 2.4 ng/mL for dexmedetomidine. The relationship between BIS and OAA/S score was obtained 20 and 40 min after changing each drug concentration. BIS values at each OAA/S score were compared between drugs. The cutoff values of BIS for OAA/S score of < or =2 were obtained by analysis of receiver operating characteristic curves. RESULTS: Nine volunteers were included in our analysis. Heart rates decreased significantly with dexmedetomidine sedation. ETco(2) was significantly increased with high doses of propofol but did not increase with high doses of dexmedetomidine. BIS values at OAA/S scores of 1, 2, 3, 4, and 5 during propofol sedation were 95.5 (90-97), 78 (71-84.5), 67 (64-70), 57 (51.5-60), and 34 (30-37), respectively. BIS values at OAA/S scores of 1, 2, 3, 4, and 5 during dexmedetomidine sedation were 95 (79-98), 62 (53.5-68.5), 45.5 (45.3-52), 39.5 (34.3-41.8), and 24.5 (22.5-30.5), respectively. BIS values were significantly less with dexmedetomidine than propofol at OAA/S responsiveness scores of 2, 3, and 4. The calculated cutoff BIS values for OAA/S scores of < or =2 were 67 (sensitivity of 86%, specificity of 97%, and area under the curve of 0.98) for propofol and 46 (sensitivity of 84%, specificity of 91%, and area under the curve of 0.96) for dexmedetomidine. CONCLUSION: The combination of both BIS and sedative scales could provide different and complementary data to the clinician evaluating the patient's response to sedation than would either tool alone, especially when dexmedetomidine is used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nelson, L. E., Lu, J., Guo, T., Saper, C. B., Franks, N. P., & Maze, M. (2003) · Anesthesiology · doi:10.1097/00000542-200302000-00024 · Cited by 854
Cited by
Mantz, J., Josserand, J., & Hamada, S. (2011) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32833e266d · Cited by 272
Classification of three anesthesia stages based on near-infrared spectroscopy signals
Liu, Z., Si, L., Shi, S., Li, J., Zhu, J., Lee, W. H., Lo, S.-L., Yan, X., Chen, B., Fu, F., et al. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3409163 · Cited by 71
Metadata
- Authors
- Kasuya, Y., Govinda, R., Rauch, S., Mascha, E. J., Sessler, D. I., & Turan, A.
- Venue
- Anesthesia & Analgesia
- Published
- 2009-12
- Volume
- 109
- Issue
- 6
- Pages
- 1811-1815
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1987106773
- Cited by
- 175
- References
- 1
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.