Abstract
BACKGROUND: We have recently shown that intraoperative bacterial transmission to patient IV stopcock sets is associated with increased patient mortality. In this study, we hypothesized that bacterial contamination of anesthesia provider hands before patient contact is a risk factor for direct intraoperative bacterial transmission. METHODS: Dartmouth-Hitchcock Medical Center is a tertiary care and level 1 trauma center with 400 inpatient beds and 28 operating suites. The first and second operative cases in each of 92 operating rooms were randomly selected for analysis. Eighty-two paired samples were analyzed. Ten pairs of cases were excluded because of broken or missing sampling protocol and lost samples. We identified cases of intraoperative bacterial transmission to the patient IV stopcock set and the anesthesia environment (adjustable pressure-limiting valve and agent dial) in each operating room pair by using a previously validated protocol. We then used biotype analysis to compare these transmitted organisms to those organisms isolated from the hands of anesthesia providers obtained before the start of each case. Provider-origin transmission was defined as potential pathogens isolated in the patient stopcock set or environment that had an identical biotype to the same organism isolated from hands of providers. We also assessed the efficacy of the current intraoperative cleaning protocol by evaluating isolated potential pathogens identified at the start of case 2. Poor intraoperative cleaning was defined as 1 or more potential pathogens found in the anesthesia environment at the start of case 2 that were not there at the beginning of case 1. We collected clinical and epidemiological data on all the cases to identify risk factors for contamination. RESULTS: One hundred sixty-four cases (82 case pairs) were studied. We identified intraoperative bacterial transmission to the IV stopcock set in 11.5 % (19/164) of cases, 47% (9/19) of which were of provider origin. We identified intraoperative bacterial transmission to the anesthesia environment in 89% (146/164) of cases, 12% (17/146) of which were of provider origin. The number of rooms that an attending anesthesiologist supervised simultaneously, the age of the patient, and patient discharge from the operating room to an intensive care unit were independent predictors of bacterial transmission events not directly linked to providers. CONCLUSION: The contaminated hands of anesthesia providers serve as a significant source of patient environmental and stopcock set contamination in the operating room. Additional sources of intraoperative bacterial transmission, including postoperative environmental cleaning practices, should be further studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effectiveness of a hospital-wide programme to improve compliance with hand hygiene
Pittet, D., Hugonnet, S., Harbarth, S., Mourouga, P., Sauvan, V., Touveneau, S., & Perneger, T. V. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02814-2 · Cited by 2,524 · cited 1×
“Similar to interventions in other fast-paced environments, future quality improvement strategies should consider barriers specific to the OR, such as pressure to work more efficiently, because prior work suggests that this may play a significant role.(18) Finally, insight into mechanisms of bacterial cross-contaminati…”
Result
Cited by
Surgical Site Infection Prevention: A Review
Seidelman, J. L., Mantyh, C. R., & Anderson, D. J. (2023) · JAMA · doi:10.1001/jama.2022.24075 · Cited by 553
Metadata
- Authors
- Loftus, R. W., Muffly, M. K., Brown, J. R., Beach, M. L., Koff, M. D., Corwin, H. L., Surgenor, S. D., Kirkland, K. B., & Yeager, M. P.
- Venue
- Anesthesia & Analgesia
- Published
- 2011-01
- Volume
- 112
- Issue
- 1
- Pages
- 98-105
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2167741446
- Cited by
- 159
- References
- 1
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.