The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing Hemodilution
The DOI matches its Crossref record.
Abstract
BACKGROUND: Total hemoglobin (tHb) is one the most frequently ordered laboratory measurements. Pulse CO-Oximetry™ (Masimo Corp., Irvine, CA) is a multi-wavelength spectrophotometric method for noninvasive and continuous hemoglobin monitoring (SpHb). In this study, we evaluated the accuracy of SpHb compared with laboratory CO-Oximeter measurement of tHb from arterial blood samples in 20 healthy volunteer subjects undergoing hemodilution. METHODS: After enrollment, approximately 500 mL of blood was drawn from subjects through an arterial or venous catheter. Each subject then rapidly received crystalloid i.v. fluid to compensate for the decrease in intravascular volume and reduce the hemoglobin concentration. Subjects received a maximum of 30 mL/kg i.v. fluid. SpHb was continuously monitored and recorded, and serial arterial blood samples were taken during the procedure. SpHb accuracy was analyzed by pairing SpHb and tHb measurements after the arterial blood draw with the resulting tHb test result. Bias, precision, and the average root-mean-square error were calculated. RESULTS: One hundred sixty-five tHb measurements were collected. The average decrease in tHb during the blood removal and hemodilution procedure was 2.4 ± 0.8 g/dL (mean ± SD). The average difference between 335 paired measurements of SpHb and tHb was -0.15 g/dL, 1 SD of the difference was 0.92 g/dL, and the average root-mean-square difference was 0.94 g/dL. The difference between SpHb and tHb was <2.0 g/dL for 97% of the measurements. The difference was <1.5 g/dL for 97% of the measurements when tHb was <10 g/dL. CONCLUSIONS: Pulse CO-Oximetry-based SpHb measurement is accurate within 1.0 g/dL (1 SD) compared with laboratory CO-Oximeter tHb measurement in subjects undergoing hemodilution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Anemia in Critical Illness: Insights into Etiology, Consequences, and Management
Hayden, S. J., Albert, T. J., Watkins, T. R., & Swenson, E. R. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201110-1915ci · Cited by 271
Metadata
- Authors
- Macknet, M. R., Allard, M., Applegate, R. L., & Rook, J.
- Venue
- Anesthesia & Analgesia
- Published
- 2010-12
- Volume
- 111
- Issue
- 6
- Pages
- 1424-1426
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2068281683
- Cited by
- 175
- References
- 0
- FWCI
- 16.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.