CoChat

A Life Cycle Assessment of Reusable and Single-Use Central Venous Catheter Insertion Kits

McGain, Forbes, McAlister, Scott, McGavin, Andrew, Story, David · 2012 · Anesthesia & Analgesia

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

BACKGROUND: For most items used in operating rooms, it is unclear whether reusable items are environmentally and financially advantageous in comparison with single-use variants. We examined the life cycles of reusable and single-use central venous catheter kits used to aid the insertion of single-use, central venous catheters in operating rooms. We did not examine the actual disposable catheter sets themselves. We assessed the entire financial and environmental costs for the kits, including the influence of the energy source used for sterilization. METHODS: For the reusable central venous catheter kit, we performed a "time-in-motion" study to determine the labor costs and measured the energy and water consumption for cleaning and sterilization at Western Health, Melbourne, Australia. For the majority of the inputs for the single-use kit, we relied upon industry and inventory-sourced databases. We modeled the life cycles of the reusable and single-use central venous catheter kits with Monte Carlo analysis. RESULTS: Inclusive of labor, the reusable central venous catheter insertion kits cost $6.35 Australian ($A) (95% confidence interval [CI], $A5.89 to $A6.86), and the single-use kits cost $A8.65. For the reusable kit, CO(2) emissions were 1211 g (95% CI, 1099 to 1323 g) and for the single-use kit 407 g (95% CI, 379 to 442 g). Water use was 27.7 L (95% CI, 27.0 to 28.6 l) for the reusable kit and 2.5 L (95% CI, 2.1 to 2.9 l) for the single-use kit. For the reusable kit, sterilization had the greatest environmental cost, and for the single-use kit, the manufacture of plastic and metal components had the largest environmental costs. Different sources of electricity to make the reusable kits patient-ready again affected the CO(2) emissions: electricity from hospital gas cogeneration resulted in 436 g CO(2) (95% CI, 410 to 473 g CO(2)), from the United States electricity grid 764 g CO(2) (95% CI, 509 to 1174 g CO(2)), and from the European electricity grid 572 g (95% CI, 470 to 713 g CO(2)). CONCLUSIONS: Inclusive of labor, the reusable central venous catheter insertion kits were less expensive than were the single-use kits. For our hospital, which uses brown coal-sourced electricity, the environmental costs of the reusable kit were considerably greater than those of the single-use kit. Efforts to reduce the environmental footprint of reusable items should be directed towards decreasing the water and energy consumed in cleaning and sterilization. The source of hospital electricity significantly alters the relative environmental effects of reusable items.

Overview

Integrity signals

Registry

Crossref · 10.1213/ane.0b013e31824e9b69

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 146

Metadata

Authors
McGain, F., McAlister, S., McGavin, A., & Story, D.
Affiliations
  • Western Health (AU)
  • The University of Melbourne (AU)
Corresponding author
McGain, Forbes
Venue
Anesthesia & Analgesia
Published
2012-05
Volume
114
Issue
5
Pages
1073-1080
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2030366116
Cited by
140
References
21
Citations by year
2026: 20 · 2025: 14 · 2024: 13 · 2023: 24 · 2022: 23 · 2021: 13 · 2020: 10 · 2019: 4 · 2018: 3 · 2017: 3 · 2016: 7 · 2015: 1 · 2014: 3 · 2013: 1 · 2012: 1
FWCI
1.59
Type
journal article
Language
en
Open access
closed
Locations
  • Anesthesia & Analgesia (publishedVersion, public-domain)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Environmental Science › Environmental Engineering › Environmental Impact and Sustainability
  • Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
Keywords
reusable medical devices, single-use medical devices, operating room equipment, CO2 emissions, water consumption, cost comparison, labor costs, environmental impact of medical devices, Monte Carlo simulation
MeSH terms
Carbon Dioxide, Catheterization, Central Venous, Computer Simulation, Conservation of Energy Resources, Costs and Cost Analysis, Disposable Equipment, Electricity, Environmental Pollution, Medical Waste, Monte Carlo Method, Stainless Steel, Sterilization, Victoria, Water, Water Pollution, Chemical, Models, Statistical, Equipment Reuse, Catheters

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.